New fluorescence parameters for monitoring photosynthesis in plants.

Photosynth Res

Department of Botany, The University of Queensland, Brisbane, QLD 4072, Australia,

Published: January 2003

Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F(V)/F(M) ratio is used.

Download full-text PDF

Source
http://dx.doi.org/10.1023/A:1026012116709DOI Listing

Publication Analysis

Top Keywords

fluorescence parameters
12
electron transport
12
fluorescence
9
chlorophyll fluorescence
8
fluorescence intensity
8
fluorescence transient
8
jip-test parameters
8
literature alteration
8
alteration activity
8
parameters
5

Similar Publications

A Structural Bioinformatics-Guided Study of Adenosine Triphosphate-Binding Cassette (ABC) Transporters and Their Substrates.

Membranes (Basel)

January 2025

Faculty of Biology, Medicine and Health, School of Biological Sciences, The University of Manchester, Manchester M13 9PT, UK.

Adenosine triphosphate-binding cassette (ABC) transporters form a ubiquitous superfamily of integral membrane proteins involved in the translocation of substrates across membranes. Human ABC transporters are closely linked to the pathogenesis of diseases such as cancer, metabolic diseases, and Alzheimer's disease. In this study, four ABC transporters were chosen based on (I) their importance in humans and (II) their score in a structural bioinformatics screen aimed at the prediction of crystallisation propensity.

View Article and Find Full Text PDF

2,4-Dichlorophenoxyacetic acid (2,4-D) is one of the popular herbicides that is widely used in agriculture and can be found in food and water. A rapid and sensitive fluorescence polarization immunoassay (FPIA) was proposed for the detection of 2,4-D in juice and water. New tracers, 2,4-D-buthylenediamin fluoresceinthiocarbamyl (2,4-D-BDF) and 2,4-D-glycine aminofluorescein (2,4-D-GAF), were obtained and characterized.

View Article and Find Full Text PDF

Glucose Sensor Design Based on Monte Carlo Simulation.

Biosensors (Basel)

January 2025

Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China.

Continuous glucose monitoring based on the minimally invasive implantation of glucose sensor is characterized by high accuracy and good stability. At present, glucose concentration monitoring based on fluorescent glucose capsule sensor is a new development trend. In this paper, we design a fluorescent glucose capsule sensor with a design optimization study.

View Article and Find Full Text PDF

Objectives: The aim of the study was to evaluate the predictive value of cell population data (CPD) parameters in comparison with procalcitonin (PCT) and C-reactive protein (CRP) for an early diagnosis of sepsis in intensive care unit (ICU). The effect of renal function on CPD, PCT and CRP, in septic and non-septic patients was also investigated.

Methods: This is a retrospective, observational and single-center study, performed with data collected from patients consecutively admitted to the ICU of the Edoardo Bassini Hospital in Milan.

View Article and Find Full Text PDF

Unlabelled: Iron deficiency anaemia (IDA) makes an individual prone to bacterial infections. The antimicrobial defence mechanism of neutrophils is orchestrated by Nicotinamide Adenine Dinucleotide Phosphate Hydrogen (NADPH) oxidative burst which is iron-dependent. The few previous studies documenting a decrease in neutrophil oxidative burst in iron-deficient children have been based mainly on the Nitro blue tetrazolium test (NBT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!