Forty-nine patients admitted for assessment of chest pain underwent coronary angiography, planar Thallium 201 myocardial scintigraphy after submaximal exercise (TE) and transoesophageal atrial pacing (TAP). Early hypofixation with redistribution after 4 h indicated ischaemia. The criterion for a myocardial infarction (MI) was a fixed perfusion defect. Coronary angiography was carried out in all patients. Sixteen patients (group 1) had no MI and over 50% narrowing of at least one main coronary vessel. Ischaemia was noted in 10 of the 16 patients during exercise, and in 14 of the 16 patients during atrial pacing. The sensitivity for the prediction of coronary stenosis was 62% for TE and 87% for TAP. Nineteen patients (group 2) had had a previous MI. Reversible ischaemia was noted in 10 of the 19 patients during exercise, and in 11 of the 19 patients during TAP. Four of 14 patients with normal coronary arteries (group 3) had a reversible ischaemia with TE, and three of these same patients developed a positive scan with TAP. The respective specificities were 71% and 78%. Comparison of segmental hypoperfusion after TE and TAP gave identical results in 72 of the 80 segments studied in group I (90%), and in 88 of the 95 segments studied in group 2 (92%). The localizing value of TAP was good in left anterior descending (12 out of 18) and right coronary disease (16 out of 19), but poor in left circumflex stenosis (3 out of 9) misclassified as right coronary disease in four patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Download full-text PDF

Source
http://dx.doi.org/10.1093/oxfordjournals.eurheartj.a060259DOI Listing

Publication Analysis

Top Keywords

atrial pacing
12
patients
10
myocardial scintigraphy
8
exercise transoesophageal
8
transoesophageal atrial
8
coronary
8
coronary angiography
8
patients group
8
ischaemia patients
8
patients exercise
8

Similar Publications

Minimizing for Maximum Benefit: An Illustrative Case-Series of Atrial Only Leadless Pacing.

Pacing Clin Electrophysiol

December 2024

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.

Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.

View Article and Find Full Text PDF

Background: Cryoballoon ablation has been widely performed in patients with paroxysmal atrial fibrillation (AF). In some challenging pulmonary veins (PVs), the procedure requires additional touch-up applications against the residual conduction gaps. It implies that there could exist difficult sites to cover with standard cryoballoon applications (CBAs), resulting in resistant conduction gaps (RCGs).

View Article and Find Full Text PDF

Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.

View Article and Find Full Text PDF

Background Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a rare genetic disorder associated with an elevated risk of life-threatening arrhythmias and progressive ventricular impairment. Risk stratification is essential to prevent major adverse cardiac events (MACE). Our study aimed to investigate the incremental value of strain measured by two-dimensional speckle-tracking echocardiography in predicting MACE in ARVC patients compared to conventional echocardiographic parameters.

View Article and Find Full Text PDF

Recently published data suggested significantly lower pacing-induced cardiomyopathy (PICM) incidence with conduction system pacing (CSP). Because most data evaluated only the impact on the left ventricle, this study aimed to assess changes in echocardiographic parameters of morphology and function for all heart chambers in patients with baseline preserved and mid-range LVEF over a medium-term follow-up period after CSP. A total of 128 consecutive patients with LVEF > 40% and successful CSP for bradyarrhythmic indication were prospectively enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!