A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Soft-x-ray hollow fiber optics with inner metal coating. | LitMetric

Soft-x-ray hollow fiber optics with inner metal coating.

Appl Opt

Department of Electrical Communications, Tohoku University, Sendai 980-8579, Japan.

Published: October 2005

AI Article Synopsis

  • A glass capillary with a nickel coating is suggested for use as soft-x-ray fiber optics in medical fields.
  • Based on theoretical calculations, nickel was selected for its efficiency with conventional x-ray tube radiation.
  • Laboratory results showed that a nickel-coated capillary of specific dimensions had a transmission efficiency of 10%, which is about twice that of a non-coated glass capillary.

Article Abstract

A glass capillary with an inner metal coating is proposed to be used as soft-x-ray fiber optics in medical applications. Based on the results of theoretical calculations, nickel was chosen as the coating material for x rays radiated from a conventional x-ray tube. A nickel-coated capillary was fabricated by electroless deposition, and focusing and collimating effects were observed from measurements of the transmission efficiency of soft x rays. The transmission of a nickel-coated capillary with an inner diameter of 0.53 mm and a length of 300 mm was 10%, which is approximately double that of an uncoated glass capillary.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.44.006193DOI Listing

Publication Analysis

Top Keywords

fiber optics
8
inner metal
8
metal coating
8
glass capillary
8
capillary inner
8
nickel-coated capillary
8
soft-x-ray hollow
4
hollow fiber
4
optics inner
4
coating glass
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!