An automatic beat detection algorithm for pressure signals.

IEEE Trans Biomed Eng

Electronics Engineering Technology Department, Oregon Institute of Technology, Portland, OR 97229, USA.

Published: October 2005

Beat detection algorithms have many clinical applications including pulse oximetry, cardiac arrhythmia detection, and cardiac output monitoring. Most of these algorithms have been developed by medical device companies and are proprietary. Thus, researchers who wish to investigate pulse contour analysis must rely on manual annotations or develop their own algorithms. We designed an automatic detection algorithm for pressure signals that locates the first peak following each heart beat. This is called the percussion peak in intracranial pressure (ICP) signals and the systolic peak in arterial blood pressure (ABP) and pulse oximetry (SpO2) signals. The algorithm incorporates a filter bank with variable cutoff frequencies, spectral estimates of the heart rate, rank-order nonlinear filters, and decision logic. We prospectively measured the performance of the algorithm compared to expert annotations of ICP, ABP, and SpO2 signals acquired from pediatric intensive care unit patients. The algorithm achieved a sensitivity of 99.36% and positive predictivity of 98.43% on a dataset consisting of 42,539 beats.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2005.855725DOI Listing

Publication Analysis

Top Keywords

beat detection
8
detection algorithm
8
algorithm pressure
8
pressure signals
8
pulse oximetry
8
spo2 signals
8
algorithm
5
signals
5
automatic beat
4
detection
4

Similar Publications

Background: Detection of atrial tachyarrhythmias (ATA) on long-term electrocardiogram (ECG) recordings is a prerequisite to reduce ATA-related adverse events. However, the burden of editing massive ECG data is not sustainable. Deep learning (DL) algorithms provide improved performances on resting ECG databases.

View Article and Find Full Text PDF

Context: Heart rate (HR) is the most vital parameter to assess hemodynamic transition at birth. ECG is considered a gold standard for HR assessment. New devices with dry electrodes are easy to apply on a wet newborn.

View Article and Find Full Text PDF

Background: The optimal approach to the diagnosis of atrial fibrillation in primary care is unclear.

Aim: To determine if external loop recorder (ELR) screening improves atrial fibrillation detection in community dwelling adults with a CHA2DS2-VASc score of greater than two.

Design: Randomised cross-over clinical trial.

View Article and Find Full Text PDF

Heartbeat inter-beat interval (IBI) extraction is a crucial technology for unobtrusive vital sign monitoring, yet its precision and robustness remain challenging. A promising approach is fusing heartbeat signals from different types of unobtrusive sensors. This paper introduces HSF-IBI, a novel and universal framework for unobtrusive IBI extraction using heterogeneous sensor fusion.

View Article and Find Full Text PDF

We developed a deep learning-based extraction of electrocardiographic (ECG) waves from ballistocardiographic (BCG) signals and explored their use in R-R interval (RRI) estimation. Preprocessed BCG and reference ECG signals were inputted into the bidirectional long short-term memory network to train the model to minimize the loss function of the mean squared error between the predicted ECG (pECG) and genuine ECG signals. Using a dataset acquired with polyvinylidene fluoride and ECG sensors in different recumbent positions from 18 participants, we generated pECG signals from preprocessed BCG signals using the learned model and evaluated the RRI estimation performance by comparing the predicted RRI with the reference RRI obtained from the ECG signal using a leave-one-subject-out cross-validation scheme.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?