Time-resolved particle image velocimetry and laser doppler anemometry study of the turbulent flow field of bileaflet mechanical mitral prostheses.

J Artif Organs

Department of Mechanical Engineering, College of Engineering, Kanto Gakuin University, 1-50-1 Mutsuura-higashi, Kanazawa-ku, Yokohama, 236-8501, Japan.

Published: January 2006

Dynamic particle image velocimetry (PIV) was applied to the study of the flow field associated with prosthetic heart valves. The results were compared with those of laser Doppler anemometry (LDA). Anatomically and antianatomically oriented Jyros (JR) and St. Jude Medical (SJM) valves were compared in the mitral position to study the effects of valve design on the downstream flow field. The experimental program used a dynamic PIV system utilizing high-speed, high-resolution video to map the true time-resolved velocity field inside the simulated ventricle. This system was complemented by a study using the more traditional LDA system for comparison. Based on the experimental data, the following general conclusions can be made. High-resolution dynamic PIV can capture true chronological changes in the velocity and turbulence fields. It also produces very detailed velocity and turbulence information comparable to the LDA results. In the vertical measuring plane that passes both the center of the aortic and mitral valves (A-A section), the two valves (the SJM and the JR) show distinct circulatory flow patterns when the valve is installed in the antianatomical orientation. Small differences in valve design can generate noticeable differences, particularly during the accelerating flow phase. The SJM valve maintains a relatively high velocity through the central orifice; the curved leaflets of the JR valve generate higher velocities with a divergent flow during the accelerating and peak flow phases. In the velocity field directly below the mitral valve and normal to the previous measuring plane (B-B section), where characteristic differences in valve design will be visible, symmetrical twin circulations were observed because of the divergent nature of the flow generated by the two inclined half-disks installed in the antianatomical orientation. The SJM valve, with a central downward flow near the valve, is contrasted with the JR valve, which has a peripheral downward circulation with higher, turbulent stresses.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-005-0298-8DOI Listing

Publication Analysis

Top Keywords

flow field
12
valve design
12
valve
10
flow
9
particle image
8
image velocimetry
8
laser doppler
8
doppler anemometry
8
valves compared
8
dynamic piv
8

Similar Publications

Setting standards for brain collection procedures in metabolomic studies.

J Cereb Blood Flow Metab

January 2025

Department of Neurology and Department of Anatomy and Neurobiology, University of Tennessee Health Science Center, Memphis, Tennessee, USA.

Current metabolomics technologies can measure hundreds of chemical entities in tissue extracts with good reliability. However, long-recognized requirements to halt enzyme activities during the initial moments of sample preparation are usually overlooked, allowing marked postmortem shifts in levels of labile metabolites representing diverse pathways. In brain many such changes occur in a matter of seconds.

View Article and Find Full Text PDF

Wheat viruses are major yield-reducing factors, with mixed infections causing substantial economic losses. Determining field virus populations is crucial for effective management and developing virus-resistant cultivars. This study utilized the high-throughput Oxford Nanopore sequencing technique (ONT) to characterize wheat viral populations in major wheat-growing counties of Kansas from 2019 to 2021.

View Article and Find Full Text PDF

A Reusable Capillary Flow-Driven Microfluidic System for Abscisic Acid Detection Using a Competitive Immunoassay.

Sensors (Basel)

January 2025

Instituto de Engenharia de Sistemas e Computadores-Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal.

Point-of-care (PoC) devices offer a promising solution for fast, portable, and easy-to-use diagnostics. These characteristics are particularly relevant in agrifood fields like viticulture where the early detection of plant stresses is crucial to crop yield. Microfluidics, with its low reagent volume requirements, is well-suited for such applications.

View Article and Find Full Text PDF

Energy-Efficient Route Planning Method for Ships Based on Level Set.

Sensors (Basel)

January 2025

The Department of Aeronautical and Automotive Engineering, Loughborough University, Loughborough LE11 3RH, UK.

To reduce the fuel consumption of ships' oceanic voyages, this study incorporates the influence of ocean currents into the traditional level set algorithm and proposes a route planning algorithm capable of identifying energy-efficient routes in complex and variable sea conditions. The approach introduces the influence factor of ocean current to optimize routing in dynamically changing marie environments. First, models for the energy consumption of ships and flow fields are established.

View Article and Find Full Text PDF

Water pipelines in water diversion projects can leak, leading to soil deformation and ground subsidence, necessitating research into soil deformation monitoring technology. This study conducted model tests to monitor soil deformation around leaking buried water pipelines using distributed fiber optic strain sensing (DFOSS) technology based on optical frequency domain reflectometry (OFDR). By arranging strain measurement fibers in a pipe-soil model, we investigated how leak location, leak size, pipe burial depth, and water flow velocity affect soil strain field monitoring results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!