The Authors describe the results of a study on the cardiotocographic tracings during labour of pregnant women, whose fetuses were affected by Down syndrome. The high incidence of cardiotocographic alterations in these fetuses does not seem to be in relation with congenital cardiac disease.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cardiotocographic alterations
8
[down syndrome
4
syndrome cardiotocographic
4
alterations author's
4
author's transl]
4
transl] authors
4
authors describe
4
describe study
4
study cardiotocographic
4
cardiotocographic tracings
4

Similar Publications

Analysis of CTG patterns in cases with metabolic acidosis at birth with and without neonatal neurological alterations.

J Matern Fetal Neonatal Med

December 2024

Department of Obstetrics and Gynecology 2U, Sant'Anna Hospital, Città della Salute e della Scienza of Turin, University of Turin, Turin, Italy.

Objective: To determine cardiotocographic patterns in newborns with metabolic acidosis, based on clinical signs of neurological alteration (NA) and the need for hypothermic treatment.

Methods: All term newborns with metabolic acidosis in a single center from 2016 to 2020 were included in the study. Three segments of intrapartum CTG (cardiotocography) were considered (first 30 min of active labor, 90 to 30 min before birth, and last 30 min before delivery) and a longitudinal analysis of CTG pattern was performed according to the 2015 FIGO classification.

View Article and Find Full Text PDF

Background: The purpose of cardiotocograph (CTG) usage is to detect any alterations in fetal heart rate (FHR) early before they are prolonged and profound. However, the use of CTG machines on a routine basis is not an evidence-supported practice. There is no Jordanian study that assesses the midwives' attitudes toward this machine.

View Article and Find Full Text PDF

Background: Intrahepatic cholestasis of pregnancy (ICP) in the first trimester occurring after ovarian hyperstimulation syndrome (OHSS) is a rare condition and few cases are reported in the literature. Hyperestrogenism may explain this problem in genetically predisposed women. The objective of this article is to report one of these rare cases and offer an overview of the other published cases.

View Article and Find Full Text PDF

Prenatal exposure to serotonin reuptake inhibitor (SRI) antidepressants increases risk for adverse neurodevelopmental outcomes, yet little is known about whether effects are present before birth. In relation to maternal SRI pharmacokinetics, this study investigated chronic and acute effects of prenatal SRI exposure on third-trimester fetal heart rate variability (HRV), while evaluating confounding effects of maternal depressed mood. At 36-weeks' gestation, cardiotocograph measures of fetal HR and HRV were obtained from 148 pregnant women [four groups: SRI-Depressed ( = 31), SRI-Non-Depressed ( = 18), Depressed (unmedicated; = 42), and Control ( = 57)] before, and ~5-h after, typical SRI dose.

View Article and Find Full Text PDF

Unusual umbilical Doppler waveform and fetal distress likely due to hypercoiled cord.

Minerva Obstet Gynecol

August 2021

Obstetric Unit, Department of Medical and Surgical Sciences, S. Orsola-Malpighi University Hospital, University of Bologna, Bologna, Italy.

Both reduced and increased umbilical cord coiling patterns have been associated with fetal distress and adverse perinatal outcomes, including fetal death. Prenatal diagnosis of cord coiling anomalies is challenging but potentially very useful for identifying those that may benefit from a more intensive monitoring. Nevertheless, there is no standardized approach for this potentially lethal complication when suspected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!