Highly resolved multi-dimensional NOE data are essential for rapid and accurate determination of spatial protein structures such as in structural genomics projects. Four-dimensional spectra contain almost no spectral overlap inherently present in lower dimensionality spectra and are highly amenable to application of automated routines for spectral resonance location and assignment. However, a high resolution 4D data set using conventional uniform sampling usually requires unacceptably long measurement time. Recently we have reported that the use of non-uniform sampling and multi-dimensional decomposition (MDD) can remedy this problem. Here we validate accuracy and robustness of the method, and demonstrate its usefulness for fully protonated protein samples. The method was applied to 11 kDa protein PA1123 from structural genomics pipeline. A systematic evaluation of spectral reconstructions obtained using 15-100% subsets of the complete reference 4D 1H-13C-13C-1H NOESY spectrum has been performed. With the experimental time saving of up to six times, the resolution and the sensitivity per unit time is shown to be similar to that of the fully recorded spectrum. For the 30% data subset we demonstrate that the intensities in the reconstructed and reference 4D spectra correspond with a correlation coefficient of 0.997 in the full range of spectral amplitudes. Intensities of the strong, middle and weak cross-peaks correlate with coefficients 0.9997, 0.9965, and 0.83. The method does not produce false peaks. 2% of weak peaks lost in the 30% reconstruction is in line with theoretically expected noise increase for the shorter measurement time. Together with good accuracy in the relative line-widths these translate to reliable distance constrains derived from sparsely sampled, high resolution 4D NOESY data.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10858-005-1363-6DOI Listing

Publication Analysis

Top Keywords

resolution sensitivity
8
multi-dimensional decomposition
8
structural genomics
8
high resolution
8
measurement time
8
optimization resolution
4
sensitivity noesy
4
noesy multi-dimensional
4
decomposition highly
4
highly resolved
4

Similar Publications

Recent advances of intelligent polymer gels as active carriers for medical imaging-guided cancer therapy: A review.

Int J Biol Macromol

January 2025

The Radiology Department of Shanxi Provincial People's Hospital, Fifth Hospital of Shanxi Medical University, Taiyuan 030001, China. Electronic address:

Cancer is a major global health challenges and various imaging-guided techniques are gaining prominence for its diagnosis and therapy with the advantages of high sensitivity, spatial resolution, and quantitative capability. The effectiveness of these approaches mainly relies on the establishment of a responsive platform. The intelligent polymer gel composites as the active carriers have drawn considerable attention owing to their outstanding versatility, three-layer network structure, mechanical adjustability and so forth, which may be contribute to loading drug, imaging probe, and targeting biomarkers in medical imaging-guided cancer therapy (IGCT).

View Article and Find Full Text PDF

Regulated sequential exocytosis of neutrophil granules is essential in orchestrating the innate immune response, while uncontrolled secretion causes inflammation. We developed and characterized Nexinhib20, a small-molecule inhibitor that targets azurophilic granule exocytosis in neutrophils by blocking the interaction between the small GTPase Rab27a and its effector JFC1. Its therapeutic potential has been demonstrated in several pre-clinical models of inflammatory disease.

View Article and Find Full Text PDF

A novel ionic liquid MALDI matrix, 3-aminoquinoline/2',4',6'-trihydroxyacetophenone monohydrate (3-AQ/THAP), was developed for the rapid qualitative and quantitative detection of miRNA from biological samples. Compared to the traditional matrix 2,5-dihydroxybenzoic acid (DHB) and previously reported oligonucleotide-specific matrices, such as 3-aminopicolinic acid (3-APA), 3-hydroxypicolinic acid (3-HPA), and 6-aza-2-thiothymine (ATT), the 3-AQ/THAP matrix offers several advantages. It produces fewer alkali metal adduct peaks, exhibits higher sensitivity, and ensures better spot-to-spot repeatability.

View Article and Find Full Text PDF

Traditional cell culture methods face significant limitations in monitoring cell secretions with spatial and temporal precision. Advanced microsystems incorporating biosensors have been developed to address these challenges, but they tend to lack versatility, and their complexity, along with the requirement for specialized equipment, limits their broader adoption. CellStudio offers an innovative, user-friendly solution that exploits Printing and Vacuum Lithography combined with bead-based assays to create modular and tunable cell patterns surrounded by biosensors.

View Article and Find Full Text PDF

Next-generation real-time gas sensors are crucial for detecting multiple gases simultaneously with high sensitivity and selectivity. In this study, ternary metal sulfide (PbSnS)-incorporated metal oxide (SnO) heterostructures were synthesized via a one-step hydrothermal method. Characterizations such as X-ray diffraction, high-resolution transmission electron microscopy, and X-ray photoelectron spectroscopy confirmed the successful formation of PbSnS/SnO heterostructures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!