Victims of radiological terrorism events require prompt diagnosis and treatment of medical and surgical conditions as well as conditions related to radiation exposure. Hospital emergency personnel should triage victims using traditional medical and trauma criteria. Radiation dose can be estimated early post-event using rapid-sort, automated biodosimetry and clinical parameters such as the clinical history, the time to emesis (TE), and lymphocyte depletion kinetics. For TE < 2 h, the effective whole-body dose is at least 3 Gy. If TE < 1 h, the whole-body dose most probably exceeds 4 Gy. Lymphocyte depletion follows dose-dependent, first order kinetics after high-level gamma and criticality incidents. Patient radiation dose can be estimated very effectively from the medical history, serial lymphocyte counts, and TE, and subsequently confirmed with chromosome-aberration bioassay, the current gold standard. These data are effectively analyzed using the Armed Forces Radiobiology Research Institute Biodosimetry Assessment Tool. The medical management of patients with acute, moderate to severe radiation exposure (effective whole-body dose >3 Gy) should emphasize the rapid administration of colony stimulating factors. All of these compounds decrease the duration of radiation-induced neutropenia and stimulate neutrophil recovery, albeit with some variability, in patients who have received myelotoxic chemotherapy, and all have demonstrated benefit in irradiated animals. For those patients developing febrile radiation-induced neutropenia, adherence to the current Infectious Diseases Society of America guidelines for high-risk neutropenia is recommended.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.hp.0000172144.94491.84 | DOI Listing |
BMJ Mil Health
January 2025
Bioengineering, Imperial College London, London, UK.
Introduction: Whole body vibration (WBV) is thought to be associated with low back pain (LBP). To mitigate against this the International Organisation for Standardisation (ISO) have created the ISO 2631 standard, recommending safe dose limits. The aim of this research is to conduct a systematic review of available literature addressing the question, is WBV associated with LBP?
Methods: A literature search was performed from January 1970 until April 2022, including studies focusing on LBP and sciatica in association with WBV, looking specifically for ones reporting on military populations.
Eur Thyroid J
January 2025
G Treglia, Repubblica e Cantone Ticino Ente Ospedaliero Cantonale, Bellinzona, Switzerland.
Background: In relapsing differentiated thyroid cancer (DTC), the in vivo evaluation of natrium-iodine symporter (NIS) expression is pivotal in the therapeutic planning and is achieved by [131/123I]Iodine whole-body scan. However, these approaches have low sensitivity due to the low sensitivity due to the low resolution of SPECT. [18F]Tetrafluoroborate (TFB) has been proposed as a viable alternative, which could outperform [131/123I]Iodine scans owing to the superior PET resolution.
View Article and Find Full Text PDFRadiat Oncol
January 2025
Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, P.R. China.
Aim: To characterize the differences of dynamic changes for absolute lymphocyte count (ALC) among esophageal squamous cell carcinoma (ESCC) patients treated with neoadjuvant chemoradiotherapy (nCRT) with or without pembrolizumab, as well as to investigate the clinical and lymphocyte-related organs dosimetric parameters that would impact ALC nadir during nCRT.
Materials And Methods: A total of 216 ESCC patients who received nCRT (with pembrolizumab 144; without pembrolizumab: 72) were identified from a prospective cohort. Weekly and 1-month post-nCRT ALC were identified.
Mol Imaging Biol
January 2025
Yale PET Center, Yale School of Medicine, New Haven, USA.
Purpose: The sphingosine-1-phosphate receptor-1 (S1PR) is involved in regulating responses to neuroimmune stimuli. There is a need for S1PR-specific radioligands with clinically suitable brain pharmcokinetic properties to complement existing radiotracers. This work evaluated a promising S1PR radiotracer, [F]TZ4877, in nonhuman primates.
View Article and Find Full Text PDFHealth Phys
January 2025
Department of Physics, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario, M5B 2K3.
This study elucidated the radiation response characteristics of a Gafchromic radiochromic film subjected to low photon doses of ≤50 mSv, which corresponds to the annual whole body effective dose limit for radiation workers in Canada. Radiochromic films are investigated for possible use as a complementary tool for the Canadian Armed Forces that can be worn in addition to their existing personal dosimetry to quickly assess personal radiation dose received from radiological hazards without reliance on electronics. The films were exposed to varying photon energies emanating from x-ray generators and radioisotopes, specifically cesium-137, cobalt-60, and americium-241.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!