Objective: The purpose of this study was to evaluate the effect of a filled adhesive (One-Step Plus; Bisco) versus an unfilled adhesive (One-Step; Bisco) on the microtensile bond strength (muTBS) to dentin using total-etch (Uni-etch; Bisco) and self-etch (Tyrian SPE; Bisco) techniques.
Methods: Twenty extracted human third molars were ground flat to expose occlusal dentin. After the dentin surfaces were polished with 600-grit SiC paper, the teeth were randomly assigned to four groups according to the bonding agent and technique being used. Dentin surfaces were bonded with One-Step Plus+total-etch; One-Step Plus+self-etch; One-Step+total-etch and One-Step+self-etch. Composite buildups were performed with Clearfil AP-X (Kuraray Medical). Following storage in distilled water at 37 degrees C for 24 h, the bonded specimens were serially sectioned into 0.7 mm-thick slabs and then trimmed to hour-glass shapes with a 1 mm2 cross-sectional area (n=20). Microtensile bond strengths were determined using the EZ-test (Shimadzu) at a cross-head speed of 1 mm/min. Data were analyzed using two-way ANOVA and Tukey's post hoc test.
Results: There were no significant differences in the muTBS between One-Step Plus and One-Step adhesives when they were used with the total-etch and self-etch techniques (p>0.05). However with the total-etch technique both adhesives yielded significantly higher bond strength values than the self-etch technique (p<0.001).
Conclusion: The filled adhesive One-Step Plus did not show any beneficial effect than the unfilled adhesive One-Step on the muTBS to dentin with total-etch and self-etch techniques. Irrespective from the adhesive type, self-etch technique revealed lower bond strengths than the total-etch technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jdent.2005.07.003 | DOI Listing |
J Funct Biomater
December 2024
Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Sapporo 060-8586, Japan.
This study investigated the effects of resin composites (RCs) containing surface pre-reacted glass ionomer (S-PRG) filler on the dentin microtensile bond strength (μTBS) of HEMA-free and HEMA-containing universal adhesives (UAs). Water sorption (WS) and solubility (SL), degree of conversion (DC), and ion release were measured. The UAs BeautiBond Xtreme (BBX; 0% HEMA), Modified Adhesive-1 (E-BBX1; 5% HEMA), Modified Adhesive-2 (E-BBX2; 10% HEMA), and two 2-step self-etch adhesives (2-SEAs): FL-BOND II (FBII; with S-PRG filler) and silica-containing adhesive (E-FBII) were used.
View Article and Find Full Text PDFJ Dent Res
December 2024
State Key Lab of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, China.
The cross-linking reagent has been proposed as a means of modifying dentin collagen, inhibiting matrix metalloproteinase activities, and enhancing bond durability during dentin bonding procedures. This study aimed to synthesize an operation-friendly dual cross-linking reagent-3-(4-formyphenoxy)-2-hydroxypropyl methacrylate (FPA)-to assess its ability to cross-link dentin collagen and reduce enzymatic activity at the bonding interface. Cytotoxicity was evaluated by a cell counting kit-8 test and calcein AM/propidium iodide assay.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, 10400, Thailand.
Objective: The purpose of this study was to examine the effect of several antiseptic mouthwashes on the dentin microtensile bond strength of self-etch adhesive, considering the influence of rinsing with water.
Methods: Forty flat dentin surfaces were produced by sectioning sound extracted third molars. They were randomly divided into four main groups: (1) artificial saliva (control); (2) 1 % hydrogen peroxide; (3) 0.
Braz Dent J
December 2024
Department of Restorative Dentistry. Piracicaba Dental School, University of Campinas, Brazil.
This study investigated the effects of nonthermal atmospheric pressure plasma (NAPP) application and dentin rehydration with water (REHY) on bond strength (BS) of adhesives. Three etch-and-rinse adhesives were tested: Scotchbond Multi-Purpose (SBM / water-based primer + adhesive resin), Gluma Bond Universal (GBU / single-bottle containing acetone as organic solvent) and Prime&Bond Universal (PBU / single-bottle containing propanol as organic solvent). Adhesives were applied: 1- to phosphoric acid-etched dentin (Control), 2- after NAPP application for 45 seconds to etched dentin or 3- after REHY with water (10 seconds) of plasma-treated etched dentin.
View Article and Find Full Text PDFPolymers (Basel)
November 2024
Department of Cariology and Operative Dentistry, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8549, Japan.
Resin core build-ups following root canal treatment still have many issues. This study evaluated whether a new low-polymerization-shrinkage resin core system (LC2) could address these issues by assessing its bonding performance to root canal dentin using microtensile bond strength tests and gap formation using swept-source optical coherence tomography (SS-OCT). Twenty-four extracted human lower premolars were used for bonding performance tests, while forty-eight sound extracted human wisdom teeth were used for gap observation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!