A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical application of acceleration sensor to detect the swing phase of stroke gait in functional electrical stimulation. | LitMetric

Functional electrical stimulation (FES) can improve the gait of stroke patients by stimulating the peroneal nerve in the swing phase of the affected leg, causing dorsiflexion of the foot that allows the toes to clear the ground. A sensor can trigger the electrical stimulation automatically during the stroke gait. We previously used a heel sensor system, which detects the contact pressure of the heel, in FES to correct foot drop gait. However, the heel sensor has disadvantages in cosmetics and durability. Therefore, we have replaced the heel sensor with an acceleration sensor that can detect the swing phase based on the acceleration speed of the affected leg, using a machine learning technique (Neural Network). We have used a signal for heel contact in a gait using the heel sensor before training with the Neural Network. The accuracy of the Neural Network detector was compared with a swing phase detector based on the heel sensor. The Neural Network detector was able to detect similarly the swing phase in the heel sensor. The largest difference in timing of the swing phase was less than 60 milliseconds in normal subjects and 80 milliseconds in stroke patients. We were able to correct foot drop gait using FES with an acceleration sensor and Neural Network detector. The present results indicate that an acceleration sensor positioned on the thigh, which is cosmetically preferable to systems in which the sensor is farther from the entry point of the electrodes, is useful for correction of stroke gait using FES.

Download full-text PDF

Source
http://dx.doi.org/10.1620/tjem.207.197DOI Listing

Publication Analysis

Top Keywords

swing phase
24
heel sensor
24
neural network
20
acceleration sensor
16
sensor
12
detect swing
12
stroke gait
12
electrical stimulation
12
gait heel
12
network detector
12