A technique suitable for diffusion tensor imaging (DTI) at high field strengths is presented in this work. The method is based on a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) k-space trajectory using EPI as the signal readout module, and hence is dubbed PROPELLER EPI. The implementation of PROPELLER EPI included a series of correction schemes to reduce possible errors associated with the intrinsically higher sensitivity of EPI to off-resonance effects. Experimental results on a 3.0 Tesla MR system showed that the PROPELLER EPI images exhibit substantially reduced geometric distortions compared with single-shot EPI, at a much lower RF specific absorption rate (SAR) than the original version of the PROPELLER fast spin-echo (FSE) technique. For DTI, the self-navigated phase-correction capability of the PROPELLER EPI sequence was shown to be effective for in vivo imaging. A higher signal-to-noise ratio (SNR) compared to single-shot EPI at an identical total scan time was achieved, which is advantageous for routine DTI applications in clinical practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3602792PMC
http://dx.doi.org/10.1002/mrm.20677DOI Listing

Publication Analysis

Top Keywords

propeller epi
20
technique suitable
8
suitable diffusion
8
diffusion tensor
8
tensor imaging
8
high field
8
reduced geometric
8
geometric distortions
8
epi
8
compared single-shot
8

Similar Publications

Purpose: Propeller fast-spin-echo diffusion magnetic resonance imaging (FSE-dMRI) is essential for the diagnosis of Cholesteatoma. However, at clinical 1.5 T MRI, its signal-to-noise ratio (SNR) remains relatively low.

View Article and Find Full Text PDF

Cardiac DTI using short-axis PROPELLER: A feasibility study.

Magn Reson Med

June 2024

Cardiovascular Innovation Research Center (CIRC), Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.

Purpose: We aimed to develop a free-breathing (FB) cardiac DTI (cDTI) method based on short-axis PROPELLER (SAP) and M2 motion compensated spin-echo EPI (SAP-M2-EPI) to mitigate geometric distortion and eliminate aliasing in acquired diffusion-weighted (DW) images, particularly in patients with a higher body mass index (BMI).

Theory And Methods: The study involved 10 healthy volunteers whose BMI values fell into specific categories: BMI <25 (4 volunteers), 25< BMI <28 (5 volunteers), and BMI >30 (1 volunteer). We compared DTI parameters, including fractional anisotropy (FA), mean diffusivity (MD), and helix angle transmurality (HAT), between SAP-M2-EPI and M2-ssEPI.

View Article and Find Full Text PDF

Comparison Between EPI DWI and PROPELLER DWI in Brain MR Imaging.

Curr Probl Diagn Radiol

December 2023

Department of Medical Imaging, Animus Kyanous Stavros Larissa, Larissa, Greece; Department of Biomedical Sciences, University of West Attica, Athens, Greece.

Objective: EPI DWI is a routinely used sequence in brain imaging but it has limitations when it comes to SNR and artifact reduction. PROPELLER DWI has the benefit of improving image quality compared to EPI DWI. The aim of this study is to compare the EPI DWI sequence in brain MR imaging with the PROPELLER DWI sequence.

View Article and Find Full Text PDF

Purpose: To develop a distortion-free motion-resolved four-dimensional diffusion-weighted PROPELLER EPI (4D-DW-PROPELLER-EPI) technique for benefiting clinical abdominal radiotherapy (RT).

Methods: An improved abdominal 4D-DWI technique based on 2D diffusion-weighted PROPELLER-EPI (2D-DW-PROPELLER-EPI), termed 4D-DW-PROPELLER-EPI, was proposed to improve the frame rate of repeated data acquisition and produce distortion-free 4D-DWI images. Since the radial or PROPELLER sampling with golden-angle rotation can achieve an efficient k-space coverage with a flexible time-resolved acquisition, the golden-angle multi-blade acquisition was used in the proposed 4D-DW-PROPELLER-EPI to improve the performance of data sorting.

View Article and Find Full Text PDF

Background: Diffusion-weighted imaging (DWI) provides quantitative measurement of random water displacement in tissue as calculated by the apparent diffusion coefficient (ADC). While heavily utilized in stroke and oncology applications, DWI is a promising tool to map microstructural changes in musculoskeletal applications including evaluation of synovial reactions resulting from total hip arthroplasty (THA). One major challenge facing the application of DWI in THA is the significant artifacts related to the conventional echo-planar imaging (EPI) readout used.

View Article and Find Full Text PDF