A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Verapamil quantification in human plasma by liquid chromatography coupled to tandem mass spectrometry. An application for bioequivalence study. | LitMetric

An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of Verapamil in human plasma using Metoprolol as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction and chromatographed on a C(8) analytical column. The mobile phase consisted of methanol-water (70:30; v/v)+12 mM formic acid. The method had a chromatographic total run time of 3.5 min and was linear within the range 1.00-500 ng/mL. Detection was carried out on a Micromass Quattro Ultima tandem mass spectrometer by multiple reaction monitoring (MRM). The intra-run imprecision was less than 5.1% calculated from the quality control (QC) samples, and 16.3% from the limit of quantification (LOQ). The accuracy determined from QC samples were between 92.9 and 103.1%, and 95.2 and 115.3% from LOQ. Concerning the inter-batch analysis, the imprecision was less than 5.8% and 17.3% from QC samples and LOQ, respectively. The accuracy varied between 98.2 and 100.8% from QC and it was 103.1% from LOQ. The protocol herein described was employed in a bioequivalence study of two tablet formulations of Verapamil.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2005.07.012DOI Listing

Publication Analysis

Top Keywords

tandem mass
12
human plasma
8
liquid chromatography
8
coupled tandem
8
mass spectrometry
8
bioequivalence study
8
internal standard
8
loq accuracy
8
verapamil quantification
4
quantification human
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!