Mankind has a long history of body decoration and body piercing has now reached epidemic popularity within a large proportion of the population. Complications such as bleeding and local infection are common, but severe infections like septicaemia, endocarditis and transmission of hepatitis may occur. We describe a 39 year old man with genital piercing who spent 43 days hospitalized because of Foumier's gangrene with necrotizing fascitis starting in the genital tract and perineum. He developed septicaemia and disseminated intravascular coagulation. A young woman with breast implants got severe mastitis after piercing her mamills. People with immunodeficiency, heart valve abnormality and present or future artificial prosthesis or skin disease should be discouraged from piercing. Since many disorders are not diagnosed when the piercing takes place, general restriction is recommended. Medical risks and consequences of piercing, especially of mucosal surfaces and cartilage, should not be underestimated.

Download full-text PDF

Source

Publication Analysis

Top Keywords

body piercing
8
piercing
7
[the risk
4
risk severe
4
severe complications
4
complications body
4
piercing underestimated]
4
underestimated] mankind
4
mankind long
4
long history
4

Similar Publications

Outbreak of perichondritis associated with ear piercings and a contaminated water system.

Epidemiol Infect

January 2025

Health Protection Operations, South West, UK Health Security Agency, Bristol, UK.

In September 2023, the UK Health Security Agency's (UKHSA) South West Health Protection Team received notification of patients with perichondritis. All five cases had attended the same cosmetic piercing studio and a multi-disciplinary outbreak control investigation was subsequently initiated. An additional five cases attending the same studio were found.

View Article and Find Full Text PDF

Body piercing has become popular among people of all ages, inspired by religious convictions, personal aesthetics, and cultural influences. Piercings in the oral cavity frequently involve the lip, buccal mucosa, frenulum, and tongue with needles, hooks, and rings. However, these piercings might cause long-term problems to both the hard and soft tissues of the mouth.

View Article and Find Full Text PDF

Stretchable Thermochromic Fluorescent Fibers Based on Self-Crystallinity Phase Change for Smart Wearable Displays.

Polymers (Basel)

December 2024

Engineering Research Center of Technical Textiles, Ministry of Education, College of Textiles, Donghua University, Shanghai 201620, China.

Smart fibers with tunable luminescence properties, as a new form of visual output, present the potential to revolutionize personal living habits in the future and are receiving more and more attention. However, a huge challenge of smart fibers as wearable materials is their stretching capability for seamless integration with the human body. Herein, stretchable thermochromic fluorescent fibers are prepared based on self-crystallinity phase change, using elastic polyurethane (PU) as the fiber matrix, to meet the dynamic requirements of the human body.

View Article and Find Full Text PDF

We describe a case of orbital cellulitis with abscess formation following eyebrow piercing complicated by internal jugular vein thrombosis and subretinal abscesses requiring enucleation with orbital abscess drainage. The popularity of body piercing is increasing and physicians should be familiar with the possibility and management of vision-threatening complications of facial piercing. Following left eyebrow piercing, a 20-year-old female experienced increasing periorbital swelling, erythema, chemosis, orbital pain, decreased vision, and concomitant fever, chills, and rhinorrhea.

View Article and Find Full Text PDF

Objective: The objective of the study was to evaluate the effect of artificial high- and low-density materials on Bone mineral density (BMD)scans in dual-energy X-ray absorptiometry (DXA) method and emergence of black-hole artifact through GATE Monte Carlo simulation.

Materials And Methods: GATE Monte Carlo code was utilized to simulate the artifact encountered in clinical scans acquired by HOLOGIC bone densitometer. Two simplified phantoms were designed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!