Laser-induced breakdown spectroscopy analysis of solids using a long-pulse (150 ns) Q-switched Nd:YAG laser.

Appl Spectrosc

Group C-ADI, MS J565, Chemistry Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.

Published: September 2005

Laser-induced breakdown spectroscopy (LIBS) measurements are typically carried out using pulses (<20 ns, >50 mJ) from a flashlamp-pumped electro-optically Q-switched Nd:YAG laser (EO-laser) or excimer laser. Here we report LIBS analyses of solids using an acousto-optically Q-switched Nd:YAG laser (AO-laser) producing 150 ns pulses of lower energy (10 mJ) at repetition rates up to 6 kHz. The high repetition rate allows increased spatial or depth sampling over a given time period compared to the EO-laser. Results of AO-laser based LIBS analysis of (1) steels, (2) soils, and (3) surface stains and dusts are described. Detection limits for Cr, Cu, Mn, Ni, and Si in steel ranged from 0.11 to 0.24% using a commercial polychromator-based detection system with limits 4--30 times lower achieved using a laboratory-based detection system. The minimum detectable masses of Ba, Cr, Mn, and Sr on a metal surface were estimated with 1.2 pg/shot achieved for Sr. Detection limits for Ba and Sr in soil were 296 and 52 ppm, respectively. The temperatures, spectra, and emission decay curves from plasmas generated by the AO- and EO-lasers are compared and some characteristics of particles ablated by the AO-laser are described.

Download full-text PDF

Source
http://dx.doi.org/10.1366/0003702055012672DOI Listing

Publication Analysis

Top Keywords

q-switched ndyag
12
ndyag laser
12
laser-induced breakdown
8
breakdown spectroscopy
8
detection limits
8
detection system
8
spectroscopy analysis
4
analysis solids
4
solids long-pulse
4
long-pulse 150
4

Similar Publications

Treatment of onychomycosis includes topical and systemic agents. However, prolonged use of oral treatment could cause adverse effects and topical antifungal agents have limited penetration. To compare the clinical efficacy and the safety of fractional CO laser combined with topical tioconazole nail solution versus Q-switched 1064 Nd: YAG laser in the treatment of fingernail onychomycosis.

View Article and Find Full Text PDF
Article Synopsis
  • Melasma is a common, chronic skin condition that mainly affects women, presenting as dark patches on the face and is often perceived as a serious cosmetic issue.
  • A survey conducted among 199 dermatologists in Turkiye revealed that the majority of patients with melasma are females between the ages of 30 to 40, with mixed melasma being the most common type.
  • The study found that topical treatments, particularly Kligman's formula, are most frequently used, while oral treatments like tranexamic acid are less common, and there's a significant recurrence rate of 41%-60%, suggesting the need for better management strategies.
View Article and Find Full Text PDF

Tattoo removal is considered a challenging field in cosmetic dermatology. Picosecond Q-switched Nd-YAG lasers targeting unique chromophores effectively manage this condition without serious complications. To evaluate the efficacy and safety of Picosecond Q-switched Nd-YAG laser in the treatment of black tattoos in the skin of middle eastern mostly skin type IV.

View Article and Find Full Text PDF

Objective: To determine the effectiveness of picosecond KTP in reducing peri-ocular dark circles caused mainly by excessive pigmentation and to compare Picosecond KTP with Thulium laser ability in reducing the intensity and extent of peri-ocular dark circles.

Materials And Methods: This split-face prospective study included twelve women with periorbital dark circles (pigmented or mixed-pigmented type). The left lower eyelid was treated using the PicoHi machine (HIRONIC Ltd), a full beam Q-switched Nd-YAG provided by KTP crystal (523 nm) at settings of 0.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to evaluate the effectiveness and safety of three different treatments for macular amyloidosis: 15% trichloroacetic acid (TCA) peel, 35% glycolic acid (GA) peel, and Q-switched Nd-YAG Laser over a course of 6 sessions.
  • A total of 75 patients participated, with TCA peels showing the greatest improvement in skin color, subjective ratings, and global assessments compared to the other two methods.
  • Although TCA peels had more adverse effects, they were still deemed the most effective and cost-efficient treatment option without any lasting side effects for patients.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!