A microflow CapNMR probe double-tuned for 1H and 13C was installed on a 400-MHz NMR spectrometer and interfaced to an automated liquid handler. Individual samples dissolved in DMSO-d6 are submitted for NMR analysis in vials containing as little as 10 microL of sample. Sets of samples are submitted in a low-volume 384-well plate. Of the 10 microL of sample per well, as with vials, 5 microL is injected into the microflow NMR probe for analysis. For quality control of chemical libraries, 1D NMR spectra are acquired under full automation from 384-well plates on as many as 130 compounds within 24 h using 128 scans per spectrum and a sample-to-sample cycle time of approximately 11 min. Because of the low volume requirements and high mass sensitivity of the microflow NMR system, 30 nmol of a typical small molecule is sufficient to obtain high-quality, well-resolved, 1D proton or 2D COSY NMR spectra in approximately 6 or 20 min of data acquisition time per experiment, respectively. Implementation of pulse programs with automated solvent peak identification and suppression allow for reliable data collection, even for samples submitted in fully protonated DMSO. The automated microflow NMR system is controlled and monitored using web-based software.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1395504PMC
http://dx.doi.org/10.1021/ac050936wDOI Listing

Publication Analysis

Top Keywords

microflow nmr
16
automated microflow
8
nmr
8
vials microl
8
microl sample
8
samples submitted
8
nmr spectra
8
nmr system
8
automated
4
nmr routine
4

Similar Publications

Background: Rectal cancer is one of the most common malignant tumors and has a high incidence rate and fatality rate. Accurate preoperative T staging of rectal cancer is critical for the selection of appropriate rectal cancer treatment. Various pre-operative imaging methods are available, and the identification of the most accurate method for clinical use is essential for patient care.

View Article and Find Full Text PDF

Sonoactivated Nanomaterials: A potent armament for wastewater treatment.

Ultrason Sonochem

October 2023

Functional Magnetic Resonance and Molecular Imaging Key Laboratory of Henan Province, Department of Magnetic Resonance Imaging, the First Affiliated Hospital of Zhengzhou University, Zhengzhou University, Zhengzhou 450000, China. Electronic address:

The world is currently facing a critical issue of water pollution, with wastewater being a major contributor. It comes from different types of pollutants, including industrial, medical, agricultural, and domestic. Effective treatment of wastewater requires efficient degradation of pollutants and carcinogens prior to discharge.

View Article and Find Full Text PDF

Pegfilgrastim is administered as an adjunct to chemotherapy to reduce the incidence of febrile neutropenia and associated infectious complications. Lupin's Pegfilgrastim is a proposed biosimilar to the U.S.

View Article and Find Full Text PDF

Polymers that carry donor-acceptor Stenhouse adducts (DASAs) are a very relevant class of light-responsive materials. Capable of undergoing reversible, photoinduced isomerisations under irradiation with visible light, DASAs allow for on-demand property changes to be performed in a non-invasive fashion. Applications include photothermal actuation, wavelength-selective biocatalysis, molecular capture and lithography.

View Article and Find Full Text PDF

A compact permanent magnet for microflow NMR relaxometry.

J Magn Reson

February 2023

Mesoscale Chemical Systems Group, University of Twente, 7500 AE Enschede, the Netherlands. Electronic address:

We design and demonstrate a compact, robust, and simple to assemble and tune permanent magnet suitable for NMR relaxometry measurements of microfluidic flows. Soft-magnetic stainless-steel plates, incorporated inside the magnet airgap, are key for obtaining substantially improved and tunable field homogeneity. The design is scalable for different NMR probe sizes with the region of suitable field homogeneity, less than 200 ppm, achievable in a capillary length of about 50 % of the total magnet length.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!