A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

L-curve analysis of radiotherapy optimization problems. | LitMetric

L-curve analysis of radiotherapy optimization problems.

Med Phys

Department of Radiation Oncology, Case Western Reserve University and University Hospitals of Cleveland, 11100 Euclid Avenue, Cleveland, Ohio 44106-6068, USA.

Published: August 2005

We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in the discrete ill-posed problems. The L-curve method is based on finding the regularization parameter which minimizes the residual norm which is a measure of accuracy of fit and the solution norm which is a measure of smoothness of solution. The main idea of the L-curve method is to plot the smoothing norm as a function of the residual norm for all values of the regularization parameter. This characteristic curve has an L-shaped dependence and the optimal value of regularization parameter can be found at the "corner" of the L-curve. We plot the L-curves for the optimization problems which simulate prostate radiotherapy cancer treatment with intensity-modulated beams. Different numerical methods are applied to calculate the point of maximum curvature of the L-curves which is a criterion to locate the corner. We show that the point of maximum curvature can be located in a most robust way using a formula derived from the singular value decomposition analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.1949750DOI Listing

Publication Analysis

Top Keywords

regularization parameter
20
optimization problems
12
l-curve method
12
optimal regularization
8
residual norm
8
norm measure
8
point maximum
8
maximum curvature
8
regularization
6
l-curve
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!