Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The aims of this study were to assess the performance of FDG PET at PET/CT imaging for the detection of pulmonary metastases and to evaluate differences in lesion detectability on attenuation-corrected (AC) and non-attenuation corrected (NAC) PET images.
Methods: The institutional PET/CT database was searched for patients with pulmonary metastases of 3-60 mm in diameter. Ninety-two patients with 438 metastases to the lungs were included in the study. The primary tumours were 33 malignant melanomas, 12 carcinomas of unknown primary, 11 colorectal carcinomas, eight differentiated thyroid carcinomas, seven aggressive non-Hodgkin's lymphomas, six head and neck cancers, three breast cancers, two prostate cancers and ten others. Lesion detectability was visually compared between PET and CT and between AC and NAC PET images using a five-point scale.
Results: Of the 438 pulmonary metastases, 174 were detected with FDG PET (39.7%), six of them on NAC images only (not significant). Visual scores were higher on NAC images in 41.4% and equal in 54.6% of lesions. The sensitivity of FDG PET increased significantly from 0.405 for metastases of 5-7 mm in diameter to 0.784 for lesions of 8-10 mm and to 0.935 for lesions measuring 11-29 mm in diameter. No metastases smaller than 5 mm in diameter were seen on PET images.
Conclusion: FDG PET/CT is useful for the assessment of pulmonary metastases. The frequency of lesion detection is similar for AC and NAC PET images. A reduced sensitivity of FDG PET has to be considered for lesions smaller than 11 mm in diameter.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00259-005-1901-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!