https://eutils.ncbi.nlm.nih.gov/entrez/eutils/efetch.fcgi?db=pubmed&id=16192851&retmode=xml&tool=Litmetric&email=readroberts32@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09https://eutils.ncbi.nlm.nih.gov/entrez/eutils/esearch.fcgi?db=pubmed&term=platelet+counts&datetype=edat&usehistory=y&retmax=5&tool=Litmetric&email=readroberts32@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09https://eutils.ncbi.nlm.nih.gov/entrez/eutils/efetch.fcgi?db=pubmed&WebEnv=MCID_67957a9b6fc22665bd0e8bcb&query_key=1&retmode=xml&retmax=5&tool=Litmetric&email=readroberts32@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09
Platelet rich plasma (PRP) has been shown to clinically accelerate healing of both soft and hard tissues. As a result, it has gained increasing popularity. However, the clinical effectiveness of each type of PRP preparation method can vary in technique and efficiency, and current methods to evaluate the platelet concentration efficiency of PRP systems have several limitations. Therefore, the purpose of this study was to validate an automated hematology analyzer, the Cell-Dyn 3700, to accurately count platelets in concentration ranges of approximately 2,000,000-4,800,000 platelets/microL. PRP platelets were counted by way of a manual counting method and on the Cell-Dyn 3700, and the statistical evaluation indicated no difference between the groups (P > 0.05). Dilution of the PRP was not required, and accurate platelet counts could be achieved up to platelet concentrations of 4,800,000 platelets/microL. PRPs must be resuspended on a rocker for at least 5 minutes before platelet counts, and the entire PRP sample must be resuspended to allow for equal distribution of platelets before counting. With use of the validated Cell-Dyn 3700, a platelet concentrate system was used to prepare 153 PRPs. The baseline whole blood platelet concentration (328,000 platelets/microL +/- 69,000 platelets/microL) and the average PRP samples (2,645,000 platelets/microL +/- 680,000 platelets/microL) were compared, resulting in an eightfold increase in concentration and an average platelet percent recovery of approximately 76%. Automated hematology analyzers can be used to accurately count platelets in PRP given the system has been validated appropriately and the PRP samples are prepared properly to provide adequate platelet suspension.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.scs.0000180007.30115.fa | DOI Listing |
Expert Rev Hematol
January 2025
Nishtar Medical University and Hospital, Multan, Pakistan.
Background: To compare plateletcount (PC), mean platelet volume (MPV), and platelet distribution width (PDW)between women with preeclampsia (PE) and normotensive pregnant women, andevaluate their effectiveness as predictors of PE.
Research Design Andmethods: This cross-sectionalstudy at Nishtar Hospital, Multan, included 141 women: 74 normotensive and 67preeclamptic. Data was collected using an automated hematology analyzer andanalyzed with SPSS version 26 and ROC curves.
Br J Hosp Med (Lond)
January 2025
Department of Obstetrics, Beilun District People's Hospital, Ningbo, Zhejiang, China.
Intrahepatic cholestasis of pregnancy (ICP) is associated with adverse perinatal outcomes, yet the correlation between ICP and the neutrophil-to-lymphocyte ratio (NLR) remains unclear. This study aims to investigate the diagnostic value of NLR in ICP. In this retrospective case-control study, 113 patients with ICP treated in Beilun District People's Hospital from January 2020 to December 2022 were recruited and categorized as the ICP group, and 209 healthy pregnant women treated during the same period were selected as the control group.
View Article and Find Full Text PDFPaediatr Anaesth
January 2025
University of Washington School of Medicine, Seattle, Washington, USA.
Introduction: The Society for Pediatric Anesthesia Quality and Safety Committee developed the Pediatric Regional Anesthesia Time-Out Checklist, consisting of 14 safety items intended to be reviewed by an anesthesia team prior to a regional anesthetic. Primarily, we hypothesized that use of this Checklist would increase the number of safety items performed compared with no checklist, evaluating the usefulness of this tool. Secondarily, we hypothesized that, after checklist training, subjects would show better clinical judgment by electing to perform a regional anesthetic in scenarios in which no programmed error existed and electing to not perform a regional anesthetic in scenarios in which a programmed error did exist.
View Article and Find Full Text PDFPharmaceuticals (Basel)
January 2025
Division of Endocrinology, Metabolism, and Rheumatology, Department of Internal Medicine, Asahikawa Medical University, Asahikawa 078-8510, Hokkaido, Japan.
Background/objectives: Metabolic dysfunction-associated steatotic liver disease (MASLD) is an important common comorbidity in subjects with type 2 diabetes, and liver fibrosis is a factor directly related to its prognosis. Glucagon-like peptide-1 receptor agonists are useful treatment options for MASLD; however, the efficacy of oral semaglutide in treating liver steatosis/fibrosis has not been fully elucidated.
Methods: A secondary analysis of a multicenter, retrospective, observational study investigating the efficacy and safety of oral semaglutide in Japanese subjects with type 2 diabetes in a real-world clinical setting (the Sapporo-Oral SEMA study) was conducted.
J Clin Med
January 2025
Ruth and Bruce Rappaport Faculty of Medicine, Technion, 1 Efron St. Bat Galim, Haifa 3525433, Israel.
: Patients with hematologic malignancy (HM) often experience high rates of thrombocytopenia, thrombocytopathy, anemia, leukopenia, and coagulopathy, which can significantly increase the risk of procedural and postoperative complications. This study aimed to evaluate the safety and outcomes of percutaneous dilatational tracheostomy (PDT) in critically ill patients with HM. : This retrospective cohort study included patients with HM who underwent PDT between 2012 and 2023 at a tertiary academic center.