Introduction: Repolarization heterogeneity (RH) is functionally linked to dispersion in refractoriness and to arrhythmogenicity. In the current study, we validate several proposed electrocardiogram (ECG) indices for RH: T-wave amplitude, -area, -complexity, and -symmetry ratio, QT dispersion, and the Tapex-end interval (the latter being an index of transmural dispersion of the repolarization (TDR)).
Methods And Results: We used ECGSIM, a mathematical simulation model of ECG genesis in a human thorax, and varied global RH by increasing the standard deviation (SD) of the repolarization instants from 20 (default) to 70 msec in steps of 10 msec. T-wave amplitude, -area, -symmetry, and Tapex-end depended linearly on SD. T-wave amplitude increased from 275 +/- 173 to 881 +/- 456 muV, T-wave area from 34 x 10(3)+/- 21 x 10(3) to 141 x 10(3)+/- 58 x 10(3)muV msec, T-wave symmetry decreased from 1.55 +/- 0.11 to 1.06 +/- 0.23, and Tapex-end increased from 84 +/- 17 to 171 +/- 52 msec. T-wave complexity increased initially but saturated at SD = 50 msec. QT dispersion increased modestly until SD = 40 msec and more rapidly for higher values of SD. TDR increased linearly with SD. Tapex-end increased linearly with TDR, but overestimated it.
Conclusion: T-wave complexity did not discriminate between differences in larger RH values. QT dispersion had low sensitivity in the transitional zone between normal and abnormal RH. In conclusion, T-wave amplitude, -area, -symmetry, and, with some limitations, Tapex-end and T-wave complexity reliably reflect changes in RH.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8167.2005.40758.x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!