Purpose: The purpose of this article is to compare the visual performance of a toric soft (TS) contact lens (SofLens 66 Toric; Bausch & Lomb, Rochester, NY), an aspheric soft (AS) contact lens (Frequency Aspheric; CooperVision, Fairport, NY) and a spectacle correction (SC) in subjects with low levels of astigmatism.
Methods: One eye of 30 subjects with refractive astigmatism of -0.75 DC or -1.00 DC was tested. After pupil dilation, each subject was fitted with all three forms of correction in random order. Subjects were masked from the contact lens type. High-contrast visual acuity (HCVA) and low-contrast visual acuity (LCVA) were recorded for each correction using 2-mm, 4-mm, and 6-mm artificial pupils.
Results: With a 2-mm pupil, HCVA was similar for the TS lens and the SC (p = 0.13); better HCVA was demonstrated with the TS lens than with the AS lens (p = 0.001). With 4-mm and 6-mm pupils, HCVA was poorer with the AS lens than with the SC (p < 0.002) and TS lenses (p < 0.0001). The difference in HCVA between the TS and AS lenses was two letters, three letters, and one line with pupil sizes of 2 mm, 4 mm, and 6 mm, respectively. LCVA was similar for the three refractive conditions with the 2-mm pupil size. With 4-mm and 6-mm pupils, LCVA was similar for the TS lens and SC, but better than the AS lens by approximately one line in each case (all p < 0.0001).
Conclusions: For small pupil sizes, there is little difference in HCVA and LCVA between various refractive corrections. However, for larger pupils, HCVA and LCVA are superior with TS contact lenses and SC versus AS contact lenses by approximately a half-line or more, which is considered to be clinically significant. Superior vision can be achieved for low astigmatic contact lens wearers using TS rather than AS contact lenses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.opx.0000177792.62460.58 | DOI Listing |
Int Ophthalmol
January 2025
Discipline of Optometry, University of KwaZulu-Natal, Durban, South Africa.
Aim: To determine the prevalence of keratoconus and its associated risk factors within the adult population of Trinidad and Tobago.
Method: A population-based cross-sectional study was conducted among adults in Trinidad and Tobago, utilizing the Keratoconus Risk Assessment Questionnaire (KRIS) for data collection. Data were exported to the Statistical Package for Social Sciences (SPSS) version 27 for analysis.
Arq Bras Oftalmol
January 2025
Department of Ophthalmology and Visual Sciences, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
Purpose: This study aimed to report the use, efficacy, and safety of intracameral voriconazole as an adjuvant treatment for deep fungal keratitis.
Methods: This was a prospective case series of seven eyes with fungal keratitis with anterior chamber involvement or a corneal ulcer refractory to conventional topical treatment. In addition to topical treatment with 0.
Arq Bras Oftalmol
January 2025
Ophthalmology and Visual Sciences Department, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
Purpose: This study aimed to modify scleral contact lenses to achieve a desired compression standard and to evaluate the effectiveness and reliability of the adjustments.
Methods: In this nonrandomized, noncomparative, and partially masked study Scleral contact lens fittings were analyzed in 20 eyes of 12 patients (50% women, 50% men) diagnosed with keratoconus. Participants were selected based on their need for scleral contact lenses (SCLs), which was determined in complete ophthalmological examinations.
Arq Bras Oftalmol
January 2025
Department of Ophthalmology, Guangdong Eye Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences. No. 106 Zhongshan Er Road, Guangzhou 510080, China.
Purpose: Although the orthokeratology effects on corneal biomechanics have been proven with clinical trials, reports of stiffness parameter change are scarce. This study investigated the short-term orthokeratology effects in pediatric myopia and compared stiffness parameter changes to those published in recent clinical investigations. This prospective study aimed to investigate corneal biomechanics changes induced by short-term overnight orthokeratology treatment, focusing on stiffness parameter at A1 and stress-strain index.
View Article and Find Full Text PDFThe dissolution/diffusion process of solid in a liquid is a kind of widespread physical phenomenon. Parameters involved in this process include the dissolution rate (), dissolution rate constant (), and diffusion coefficient (), whose accurate measurement is particularly important in fields such as biopharmaceuticals, materials science, agriculture, etc. However, the commonly used measurement methods at present cannot obtain these parameters simultaneously.