Objective: To investigate the expression of chromogranin A (CgA) and synaptophysin (Syn) for differential diagnosis of different kinds of adrenal gland tumors.
Methods: The samples of 69 adrenal gland tumors and 4 normal adrenal glands were immunohistochemically analyzed for the expression of chromogranin A and synaptophysin. The statistical analysis of the data was performed using chi-square test.
Results: In the normal adrenal gland, CgA and Syn was exclusively detected in the medulla. CgA was detected in all pheochromocytomas 25/25 (100%), and gave less or no expression in adrenocortical tumors. Syn was detected in adrenocortical adenomas 27/28 (96.4%), adrenocortical carcinoma 7/8 (87.5%), pheochromocytoma 24/25 (96.0%) and adrenal metastatic carcinoma 6/8 (75.0%), respectively.
Conclusion: There is statistically significant difference of CgA expression between adrenalcortical and adrenal medullary tumors, and also between benign and malignant pheochromocytomas. CgA and Syn are immunohistochemically reliable markers in the differential diagnosis of various kinds of adrenal gland tumors.
Download full-text PDF |
Source |
---|
JCO Clin Cancer Inform
January 2025
Machine Learning Department, H. Lee Moffit Cancer Center and Research Institute, Tampa, FL.
Purpose: Adaptive radiotherapy accounts for interfractional anatomic changes. We hypothesize that changes in the gross tumor volumes identified during daily scans could be analyzed using delta-radiomics to predict disease progression events. We evaluated whether an auxiliary data set could improve prediction performance.
View Article and Find Full Text PDFImmunol Res
January 2025
Department of Medical Chemistry, Yerevan State Medical University After M. Heratsi, Koryun Str., 0025, Yerevan, Armenia.
Experimental studies of chronic noise exposure in modern urban life testified about oxidative stress due to the corresponding hormones effects leading to accumulation of reactive oxygen species and endothelial dysfunction. This study aims to evaluate the protective effect of α2-adrenoblockers to modulate oxidative stress and corticosterone levels due to chronic noise exposure. To achieve this, we examined the effects of beditin (2-aminothiozolyl-1,4-benzodioxane) and mesedin (2-(2-methyl-amino-thiozolyl)-1,4-benzodioxane hydrochloride), along with changes in corticosterone, Ca2 + content, and morphological alterations in various tissues under noise-induced stress.
View Article and Find Full Text PDFVet Sci
January 2025
Department of Clinics, Faculty of Veterinary Medicine, "Ion Ionescu de la Brad" Iasi University of Life Sciences, 700490 Iasi, Romania.
A 3-year-old spayed male mixed-breed Labrador presented to the Emergency and Critical Care Unit with lethargy, loss of appetite, vomiting, a recent history of presyncopal episodes, and severe exercise intolerance. On admission, the patient had bradycardia, low blood pressure, and mild abdominal pain. Serum biochemistry information revealed severe hyperkalemia, hyponatremia, hypoglycemia, and mildly increased liver and kidney parameters.
View Article and Find Full Text PDFMetabolites
January 2025
Segal Cancer Proteomics Centre, Lady Davis Institute for Medical Research, Jewish General Hospital, McGill University, Montreal, QC H3T 1E2, Canada.
Quantifying urinary catecholamines and metanephrines is essential for the clinical screening and diagnosis of neuroendocrine tumours. HPLC with electrochemical detection (HPLC-ECD) is commonly used for this type of analysis but requires extensive sample cleanup. Simple and rapid dilute-and-shoot LC-multiple-reaction monitoring (MRM)-MS assays have been developed for quantitating these analytes in urine but have not yet been validated according to the Clinical and Laboratory Standards Institute (CLSI) guidelines.
View Article and Find Full Text PDFCurr Oncol
January 2025
Department of Radiology, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!