Purpose: Compare, in a rabbit model, the inflammatory response and adhesions formation following surgical fixation of polypropilene and Vypro mesh in the inguinal preperitoneal space.

Methods: Fourteen male New Zealand rabbits, weighing between 2.000 to 2.500 g were used. A midline incision was made and the peritoneal cavity was exposed. The 2.0 x 1.0 cm polypropylene mesh was fixed in the left flank and secured to the margins with 3-0 prolene in a separate pattern. In the right flank, a 2.0 x 1.0 cm Vypro II mesh was sewn in the same way. After the post surgical period, the animals were again anesthetized and underwent laparoscopic approach, in order to identify and evaluate adhesions degree. Both fixed prosthesis were excised bilaterally with the abdominal wall segment, including peritoneum, aponeurosis and muscle and sent to a pathologist.

Results: Operative time ranged from 15 to 25 minutes and no difficulties in applying the mesh were found. From the 14 polypropylene meshes fixed to the intact peritoneum, 11 had adhesions to the abdominal cavity (78.6%). Concerning Vypro mesh, 12 animals developed adhesions from the 14 with mesh fixation (85.7%). Histological examination of tissues harvested revealed fibroblasts, collagen, macrophages and lymphocytes between the threads of the mesh.

Conclusion: Polypropylene and Vypro mesh, when implanted in the peritoneal cavity of rabbits provoke similar amount of adhesions. Vypro mesh tissues had higher fibrosis resulting in better mesh incorporation to the abdominal wall.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0102-86502005000500002DOI Listing

Publication Analysis

Top Keywords

vypro mesh
20
mesh
9
inflammatory response
8
response adhesions
8
adhesions formation
8
peritoneal cavity
8
abdominal wall
8
adhesions
6
vypro
5
comparative study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!