Aims: We sought to determine the incidence, mechanisms, and time to syncope recurrence in patients with spontaneous syncopal monomorphic ventricular tachycardia (SyMVT) treated with an implantable cardiac defibrillator (ICD).

Methods And Results: Incidence and causes of syncope following ICD implantation in consecutive patients (n=26) with spontaneous SyMVT were compared with those found in consecutive patients (n=50) with spontaneous non-syncopal monomorphic ventricular tachycardia (NSyMVT). Patients with SyMVT had a higher incidence of syncope (46% patients) than those with NSyMVT (2% patients) at 31+/-21 and 34+/-23 months follow-up, respectively (hazard ratio, 0.19; 95% confidence interval, 0.04-0.42; P=0.0001). Among the former, four patients (15%) had non-arrhythmic syncope and eight patients had arrhythmic syncope (31%), which was associated with either ICD proarrhythmia (seven episodes of VT acceleration or VF degeneration by ATP or low/high-energy shocks in three patients) or spontaneous VT and VF (five episodes in five patients). Median time to the first arrhythmic syncope was 376 days. Arrhythmic syncope presented after a first non-syncopal VT recurrence in six patients (75%).

Conclusion: Syncope following ICD implantation is common in patients with SyMVT in contrast to patients with NSyMVT. Late syncope presentation supports reassessment of driving restrictions in this setting.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurheartj/ehi500DOI Listing

Publication Analysis

Top Keywords

patients
14
patients spontaneous
12
monomorphic ventricular
12
ventricular tachycardia
12
arrhythmic syncope
12
syncope
10
spontaneous syncopal
8
syncopal monomorphic
8
recurrence patients
8
incidence syncope
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!