There is a lack of systematic investigations comparing optical coherence tomography (OCT) with histology. OCT assessments were performed on the upper back of 16 healthy subjects. Epidermis thickness (ET) was assessed using three methods: first, peak-to-valley analysis of the A-scan (ET-OCT-V); second, manual measurements in the OCT images (ET-OCT-M); third, light microscopic determination using routine histology (ET-Histo). The relationship between the different methods was assessed by means of the Pearson correlation procedure and Bland and Altman plots. We observed a strong correlation between ET-Histo (79.4+/-21.9 microm) and ET-OCT-V (79.2+/-15.5 microm, r=0.77) and ET-OCT-M (82.9+/-15.8 microm, r=0.75), respectively. Bland and Altman plots revealed a bias of -0.19 microm (95% limits of agreement: -27.94 microm to 27.56 microm) for ET-OCT-V versus ET-Histo and a bias of 3.44 microm (95% limits of agreement: -24.9 microm to 31.78 microm) for ET-OCT-M versus ET-Histo. Despite the strong correlation and low bias observed, the 95% limits of agreement demonstrated an unsatisfactory numerical agreement between the two OCT methods and routine histology indicating that these methods cannot be employed interchangeably. Regarding practicability, precision, and indication spectrum, ET-OCT-V and ET-OCT-M are of different clinical value.

Download full-text PDF

Source
http://dx.doi.org/10.1117/1.2039086DOI Listing

Publication Analysis

Top Keywords

routine histology
12
95% limits
12
limits agreement
12
microm
9
optical coherence
8
coherence tomography
8
bland altman
8
altman plots
8
strong correlation
8
microm et-oct-v
8

Similar Publications

A cross-sectional study on 156 smallholder dairy farms in Rwanda was carried out to assess the association between farm management practices and milk yield and quality. A pre-tested questionnaire was used to collect data on cow characteristics and farm management practices. Milk yield was recorded at household level, milk composition was monitored using a Lactoscan device (Milk Analyzer).

View Article and Find Full Text PDF

Rapid structural analysis of purified proteins and their complexes has become increasingly common thanks to key methodological advances in cryo-electron microscopy (cryo-EM) and associated data processing software packages. In contrast, analogous structural analysis in cells via cryo-electron tomography (cryo-ET) remains challenging due to critical technical bottlenecks, including low-throughput sample preparation and imaging, and laborious data processing methods. Here, we describe a rapid in situ cryo-ET sample preparation and data analysis workflow that results in the routine determination of sub-nm resolution ribosomal structures.

View Article and Find Full Text PDF

Background: This paper describes the rationale and design of the RECOVER study. Currently, there is no consensus regarding the optimal treatment for high-risk, non-metastatic prostate cancer (PCa). The study primarily aims to evaluate and compare the impact of treatment with robot-assisted radical prostatectomy (RP) versus external beam radiation therapy (EBRT) with androgen deprivation therapy (ADT) for men with high-risk, non-metastatic PCa regarding health-related quality of life (HRQoL) and functional outcomes.

View Article and Find Full Text PDF

Objective: To characterize the systemic treatment patterns and current state of moderate-to-severe psoriasis patients in real-world settings in Greece.

Methods: CRYSTAL-Greece was a multicenter, cross-sectional and retrospective chart review study assessing Psoriasis Area and Index (PASI), Dermatology Life Quality Index (DLQI) and EuroQol-5-Dimensions 5-Levels (EQ-5D-5L). Eligible patients were consented adults (18-75 years old) on continuous treatment with any approved systemic therapy regimen for ≥24 weeks.

View Article and Find Full Text PDF

Neurodegeneration is presumed to be the pathological process measure most proximal to clinical symptom onset in Alzheimer Disease (AD). Structural MRI is routinely collected in research and clinical trial settings. Several quantitative MRI-based measures of atrophy have been proposed, but their low correspondence with each other has been previously documented.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!