Background: Molecular epidemiologic investigations can link geographically separate foodborne hepatitis A outbreaks but have not been used while field investigations are in progress. In 2003, outbreaks of foodborne hepatitis A were reported in multiple states.

Methods: Case-control studies were conducted in 3 states. Hepatitis A virus was sequenced from serologic specimens from individuals associated with outbreaks and from individuals concurrently ill with hepatitis A in non-outbreak settings in the United States and Mexico.

Results: Case-control studies in Tennessee (TN), North Carolina (NC), and Georgia (GA) found green onions to be associated with illness among restaurant patrons (TN: odds ratio [OR], 65.5 [95% confidence interval {CI}, 8.9-482.5; NC: OR, 2.4 [95% CI, 0.3-21.9]; GA: OR, 20.9 [95% CI, 3.9-110.3]). Viral sequences from TN case patients differed by 2 nt, compared with those from case patients in NC and GA. A third sequence, differing from the TN and GA/NC sequences by 1 nt, was identified among case patients in a subsequent outbreak in Pennsylvania. Each outbreak sequence was identical to > or =1 sequence isolated from northern Mexican resident(s) with hepatitis A. The sources of green onions served in restaurants in TN and GA were 3 farms in northern Mexico.

Conclusions: Ongoing viral strain surveillance facilitated the rapid implementation of control measures. Incorporation of molecular epidemiologic methods into routine hepatitis A surveillance would improve the detection of hepatitis A outbreaks and increase our understanding of hepatitis A epidemiology in the United States.

Download full-text PDF

Source
http://dx.doi.org/10.1086/462425DOI Listing

Publication Analysis

Top Keywords

foodborne hepatitis
12
hepatitis outbreaks
12
united states
12
case patients
12
hepatitis
9
molecular epidemiologic
8
case-control studies
8
green onions
8
outbreaks
5
molecular epidemiology
4

Similar Publications

Foodborne viruses are significant contributors to global food safety incidents, posing a serious burden on human health and food safety. In this study, a multiplex reverse transcription-droplet digital PCR (RT-ddPCR) assay based on the MS2 phage as a process control virus (PCV) was developed to achieve the simultaneous detection of hepatitis A virus (HAV) and hepatitis E virus (HEV) in bivalve shellfish. By optimizing the reaction system and procedures, the best reaction conditions were selected, and the specificity, sensitivity, and reproducibility of the method were assessed.

View Article and Find Full Text PDF

Case of Fatal Hepatitis Related to HEV-3 Infection in Central Italy.

Viruses

November 2024

Microbiology and Clinical Microbiology Section, Department of Medicine and Surgery, University of Perugia, 06132 Perugia, Italy.

Hepatitis E virus (HEV) is a global health problem, causing an estimated 20 million infections annually. Thus, the management of HEV requires special consideration. In developed countries, hepatitis E is mainly recognized as a foodborne disease (mainly transmitted via undercooked meat consumption) that is generally caused by genotype 3 and 4 circulating in various animals, including pigs and wild boars.

View Article and Find Full Text PDF

spp. and hepatitis E virus (HEV) are significant foodborne zoonotic pathogens that impact the health of livestock, farmers, and the general public. This study aimed to identify biosecurity measures (BSMs) against these pathogens on swine farms in Europe, the United States, and Canada.

View Article and Find Full Text PDF

A Cell-Based Electrochemical Biosensor for the Detection of Infectious Hepatitis A Virus.

Biosensors (Basel)

November 2024

Nano Electrochemistry Laboratory, College of Engineering, University of Georgia, Athens, GA 30602, USA.

Hepatitis A virus (HAV), a major cause of acute liver infections, is transmitted through the fecal-oral route and close contact with infected individuals. Current HAV standardized methods rely on the detection of virus antigen or RNA, which do not differentiate between infectious and non-infectious HAV. The objective of this study was to develop a prototype cell-based electrochemical biosensor for detection of infectious HAV.

View Article and Find Full Text PDF

To achieve rapid and simultaneous detection of NoV GI, NoV GII, and HAV, a quadruple real-time fluorescence quantitative PCR (RT-qPCR) assay was developed using MS2 bacteriophage as a process control virus. The quadruple RT-qPCR assay effectively detected NoV GI, NoV GII, HAV, and MS2 RNA with detection limits of 10 copies/μL, 10 copies/μL, 10 copies/μL, and 10 copies/μL, respectively, within 1 hour 50 minutes. The quadruple RT-qPCR assay could specifically detect NoV GI, NoV GII, HAV, and MS2 without cross-reactions with other common pathogens, demonstrating good reproducibility with intra-assay and inter-assay coefficients of variation all below 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!