The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities.

Download full-text PDF

Source

Publication Analysis

Top Keywords

generation 64-row
8
64-row scanners
8
coronary angiography
8
introduction coronary
4
coronary imaging
4
imaging 64-slice
4
64-slice computed
4
computed tomography
4
tomography aim
4
aim article
4

Similar Publications

Background: Previous studies have shown that neo-commissural orientation of transcatheter heart valve (THV) can influence coronary obstruction during transcatheter aortic valve replacement (TAVR), long-term durability of THV, and coronary artery access for reintervention after TAVR. Specific initial orientations of Evolut R/Pro and Acurate Neo aortic valves can improve commissural alignment. However, the method of achieving commissural alignment with the Venus-A valve remains unknown.

View Article and Find Full Text PDF

Background: Whether deep learning-based CT reconstruction could improve lesion conspicuity on abdominal CT when the radiation dose is reduced is controversial.

Objectives: To determine whether DLIR can provide better image quality and reduce radiation dose in contrast-enhanced abdominal CT compared with the second generation of adaptive statistical iterative reconstruction (ASiR-V).

Aims: This study aims to determine whether deep-learning image reconstruction (DLIR) can improve image quality.

View Article and Find Full Text PDF
Article Synopsis
  • Soft tissue fillers are commonly used to address volume loss in the chin due to aging and congenital conditions.
  • The study involved scanning 40 cadaver heads to analyze arterial anatomy and reduce risks of complications like intravascular embolization during filler injections.
  • Findings indicated a higher presence of superficial arteries compared to deep ones, leading to recommendations for safer chin filler injection techniques that enhance patient satisfaction.
View Article and Find Full Text PDF

Purpose: We retrospectively evaluated the visualization of pediatric coronary computed tomography angiography (CCTA) images by using the 64-detector row CT scanner between the electrocardiogram-gated helical scan and non-electrocardiogram-gated helical scan.

Methods: From January 2015 to March 2019, 100 children who underwent CT angiography examination were retrospectively enrolled. Group A consisted of 50 patients with electrocardiogram-gated helical scan.

View Article and Find Full Text PDF

Background: The development of ultra-high-resolution CT (U-HRCT) is expected to improve the accuracy of coronary stenosis evaluation. This study aimed to evaluate the accuracy of the stenosis severities of coronary artery phantoms estimated using U-HRCT by comparing them to those estimated with conventional CT.

Methods: Coronary artery phantoms with non-calcified and calcified lesions were scanned with conventional CT (64-row ​× ​0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!