To assess the accuracy of multirow detector computed tomography (MDCT) for the evaluation of renal anatomy for preoperative donor assessment in living related kidney transplantation. MDCT-scans (4- and 16-slice-CT) of 51 consecutive living kidney donors (age, 51.6 +/- 9.7 years; range, 28-68 years) were analysed by three blinded observers and compared with digital subtraction angiography (DSA) and surgery. Contrast-enhanced MDCT was performed with 1 mm slice thickness reconstruction interval during arterial and venous phases. Supernumerary renal arteries, veins, early branching of vessels and abnormalities of the ureters were documented. The overall accuracy of computed tomography angiography (CTA) for detection and classification of surgically relevant arterial variants was 97% (99/102). The interpretation of 16-channel MDCT images was correct in all cases (accuracy, 100%), while the four-channel CTA had three incorrect results regarding the differentiation of early branching vessels from double renal arteries (accuracy, 93%). The overall accuracy of DSA was 91%. Renal vein abnormalities were correctly diagnosed with MDCT in 100% compared with 89% correct findings with DSA. There were three kidneys with incomplete ureter duplication, detected both with MDCT and DSA. MDCT demonstrated superior accuracy compared with non-selective DSA for the preoperative assessment of renal anatomy in living kidney donors; and for the distinction of supernumerary arteries versus early branching patterns, 16-channel CTA data were better than those of the four-channel system.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1432-2277.2005.00196.xDOI Listing

Publication Analysis

Top Keywords

living kidney
16
kidney donors
12
computed tomography
12
early branching
12
multirow detector
8
detector computed
8
digital subtraction
8
subtraction angiography
8
renal anatomy
8
renal arteries
8

Similar Publications

Background: The existing criteria for living kidney donors (LKDs)in Japan are controversial. We evaluated the roles of computed tomography volumetry (CTV) and 99 m Tc-diethylenetriamine penta-acetic acid (DTPA) scintigraphy in assessing preoperative and postoperative renal function and predicting early recovery of residual renal function.

Methods: We retrospectively reviewed the medical charts of 175 consecutive LKDs who underwent donor nephrectomy (DN) at our institution between 2006 and 2022.

View Article and Find Full Text PDF

Importance: For patients hospitalized with acute decompensated heart failure (ADHF), the presence of kidney dysfunction can substantially shape prognosis and treatment options. Yet little is known about the lived experiences of these medically vulnerable patients.

Objective: To elicit accounts of the illness and care experiences of patients currently or recently hospitalized with ADHF and kidney dysfunction in order to identify potential opportunities to improve care.

View Article and Find Full Text PDF

Background: Recent studies suggest that approximately 10% of patients with chronic kidney disease (CKD) have disease-causing genetic variants, an observation relevant to evaluation of kidney transplant candidates.

Methods: We retrospectively investigated the diagnostic yield of genetic testing in kidney transplant candidates evaluated at our program (January 1, 2021-December 8, 2022). Inclusion criteria were as follows: first-degree relative(s) with CKD/end-stage kidney disease (ESKD), early-onset CKD, focal segmental glomerulosclerosis, cystic kidney disease, alternative complement pathway-associated diseases, or ESKD of unknown cause.

View Article and Find Full Text PDF

Comparing Five Generations of ActiGraph Devices using an Orbital Shaker.

Med Sci Sports Exerc

January 2025

Energy Metabolism Section, National Institute of Diabetes, Digestive and Kidney Diseases, Diabetes, Endocrinology, and Obesity Branch, National Institutes of Health (NIH), Bethesda, MD.

Introduction: ActiGraph accelerometers are used extensively to objectively assess physical activity, sedentary behavior, and sleep. Here, we present an objective validation of five generations of ActiGraph sensors to characterize potential differences in output arising from changes to hardware or firmware.

Methods: An orbital shaker generated accelerations from 0 to 3700 milli-g in a randomized order to test the wGT3X-BT, GT9X, CentrePoint Insight Watch (CPIW) 1.

View Article and Find Full Text PDF

Introduction: When GFR is measured (mGFR) using iohexol plasma clearance, results are reported both as a "non-indexed" (mL/min) and "body-surface area (BSA) indexed" to 1.73 m2. When these two values differ, there is no consensus as to which is preferable to use to determine suitability for living kidney donation (LKD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!