Non-invasive assessment of motor unit anatomy in jaw-elevator muscles.

J Oral Rehabil

Specialization School of Orthodontics, Department of Biomedical Sciences and Human Oncology, University of Turin, Turin, Italy.

Published: October 2005

The estimation of fibre length in jaw-elevator muscles is important for modelling studies and clinical applications. The objective of this study was to identify, from multi-channel surface EMG recordings, the main innervation zone(s) of the superficial masseter and anterior temporalis muscles, and to estimate the fibre length of these muscles. Surface EMG signals were collected from 13 subjects with a 16-electrode linear array. The innervation zones of the masseter and anterior temporalis were identified and their variability intra- and inter-subject outlined. More than one main innervation zone location was identified in the masseter of all subjects and in the temporalis anterior of 12 subjects. Average estimated fibre lengths, for the right (left) side, were (mean+/-SD) 27.3+/-2.4 mm (27.0+/-1.7 mm) and 25.9+/-2.3 mm (26.6+/-1.6 mm), for the superficial masseter and temporalis anterior muscle, respectively. The range of innervation zone locations was up to approximately 50% of the fibre length, both within and between subjects. Fibre length estimates well matched with published data on cadavers. It was concluded that multi-channel surface EMG provides important and reliable information on the anatomy of single motor units in jaw-elevator muscles.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2842.2005.01490.xDOI Listing

Publication Analysis

Top Keywords

fibre length
16
jaw-elevator muscles
12
surface emg
12
multi-channel surface
8
main innervation
8
innervation zones
8
superficial masseter
8
masseter anterior
8
anterior temporalis
8
innervation zone
8

Similar Publications

Polyimide (PI)-based gas separation membranes are of great interest in the field of H purification owing to their good thermal stability, chemical stability, and mechanical properties. Among polyimide-based membranes, intrinsically microporous polyimides are easily soluble in common organic solvents, showing great potential for fabricating hollow fiber gas separation membranes. However, based on the solution-diffusion model, improving the free volume or the movability of polymer chains can improve gas permeability, but would result in poor thermal stability.

View Article and Find Full Text PDF

Telomere length has been related to human health and ageing in multiple studies. However, these studies have analyzed a small set of variables, according to pre-formulated hypotheses. We used data from NHANES 1999-2002 to perform a preregistered cross-sectional analysis.

View Article and Find Full Text PDF

A novel all-fiber optic current sensor (FOCS) is designed specifically for the measurement of large transient currents based on the Faraday effect. A reciprocal symmetric structure is incorporated into the optical sensing loop, and the current dependent phase demodulation is achieved by using a passive optical fiber coupler and the homodyne detection scheme. This design offers several advantages, including structural simplicity, high voltage insulation, low noise, high linearity, and excellent frequency response, and is highly suitable for use in any system of high-voltage, high-power, and high-frequency in nature.

View Article and Find Full Text PDF

Resolving the molecular basis of a Mendelian condition remains challenging owing to the diverse mechanisms by which genetic variants cause disease. To address this, we developed a synchronized long-read genome, methylome, epigenome and transcriptome sequencing approach, which enables accurate single-nucleotide, insertion-deletion and structural variant calling and diploid de novo genome assembly. This permits the simultaneous elucidation of haplotype-resolved CpG methylation, chromatin accessibility and full-length transcript information in a single long-read sequencing run.

View Article and Find Full Text PDF

Background/aims: To identify the risk factors for neuropathic corneal pain (NCP) following corneal refractive surgery and to report its clinical manifestations, imaging and proteomic characteristics.

Methods: This 1 year prospective cohort study included 100 eyes that underwent small incision lenticule extraction (SMILE) or laser-assisted in situ keratomileusis (LASIK). Ocular surface assessments, in-vivo confocal microscopy scans, tear neuromediators and proteomics analyses were performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!