Background And Purpose: The purpose of this work was a comparison of realistic IMRT plans based on the same CT-image data set and a common predefined set of dose objectives for the planning target volume and the organs at risk. This work was part of the larger European QUASIMODO IMRT verification project.

Materials And Methods: Eleven IMRT plans were produced by nine different European groups, each applying a representative set of clinically used IMRT treatment planning systems. The plans produced were to be deliverable in a clinically acceptable treatment time with the local technical equipment. All plans were characterized using a set of different quality measures such as dose-volume histograms, number of monitor units and treatment time.

Results: Only one plan was able to fulfil all dose objectives strictly; six plans failed some of the objectives but were still considered to be clinically acceptable; four plans were not able to reach the objectives. Additional quality scores such as the number of monitor units and treatment time showed large variations, which mainly depend on the delivery technique.

Conclusion: The presented planning study showed that with nearly all presently available IMRT planning and delivery systems comparable dose distributions could be achieved if the planning goals are clearly defined in advance.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2005.08.003DOI Listing

Publication Analysis

Top Keywords

imrt treatment
8
imrt plans
8
dose objectives
8
plans produced
8
clinically acceptable
8
treatment time
8
number monitor
8
monitor units
8
units treatment
8
imrt
6

Similar Publications

Purpose: To evaluate the impact of patient setup errors on the dosimetry and radiobiological models of intensity-modulated radiotherapy (IMRT) for esophageal cancer.

Methods And Materials: This retrospective study with 56 patients in thermoplastic mask (TM) and vacuum bag (VB) groups utilized real setup-error (RSE) data from cone-beam CT scans to generate simulated setup-error (SSE) data following a normal distribution. The SSE data were applied to simulate all treatment fractions per patient by shifting the plan isocenter and recalculating the dose.

View Article and Find Full Text PDF

Purpose: To investigate the impact of Intensity-Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) on hippocampal radiation dosage and psychological status in patients newly diagnosed with nasopharyngeal carcinoma (NPC).

Patients And Methods: A retrospective analysis was conducted on 269 NPC patients who received initial treatment between January 2013 and April 2022. Patients were categorized into the IMRT group and the VMAT group based on the radiotherapy technique employed.

View Article and Find Full Text PDF

Background: The purpose of this study was to compare outcomes and adverse events between three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) in patients undergoing long-course neoadjuvant radiation therapy (NA-RT) for locally advanced rectal adenocarcinoma (LARC).

Methods: We retrospectively analyzed a total of 47 consecutive patients who received NA-RT for LARC between January 2011 and September 2022. Seven and 40 patients were diagnosed with clinical stages II and III, respectively.

View Article and Find Full Text PDF

This study aimed to evaluate the recent trends in single-fraction conventional radiotherapy (CRT) as palliative treatment in Japan, using data from the National Database published by the Ministry of Health, Labor, and Welfare. Data from fiscal year (FY) 2014 to FY2022, specifically related to the utilization of single-fraction CRT, were analyzed. Multi-fraction CRT, stereotactic body radiotherapy (SBRT), intensity-modulated radiotherapy (IMRT), and brachytherapy were excluded.

View Article and Find Full Text PDF

This retrospective study aimed to compare the clinical outcomes of intensity-modulated radiation therapy (IMRT) and proton beam therapy (PBT). A total of 606 patients diagnosed with prostate cancer between January 2008 and December 2018 were included. Of these patients, 510 received PBT up to a dose of 70-78 Gy (relative biological effectiveness) and 96 patients received IMRT up to a dose of 70-78 Gy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!