Empirical QSAR models are only valid in the domain they were trained and validated. Application of the model to substances outside the domain of the model can lead to grossly erroneous predictions. Partial least squares (PLS) regression provides tools for prediction diagnostics that can be used to decide whether or not a substance is within the model domain, i.e. if the model prediction can be trusted. QSAR models for four different environmental end-points are used to demonstrate the importance of appropriate training set selection and how the reliability of QSAR predictions can be increased by outlier diagnostics. All models showed consistent results; test set prediction errors were very similar in magnitude to training set estimation errors when prediction outlier diagnostics were used to detect and remove outliers in the prediction data. Test set prediction errors for substances classified as outliers were much larger. The difference in the number of outliers between models with a randomly and systematically selected training illustrates well the need of representative training data.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2005.07.002DOI Listing

Publication Analysis

Top Keywords

training set
12
set selection
8
qsar predictions
8
qsar models
8
domain model
8
outlier diagnostics
8
test set
8
set prediction
8
prediction errors
8
prediction
6

Similar Publications

Chemical release data are essential for performing chemical risk assessments to understand the potential exposures arising from industrial processes. Often, these data are unknown or unavailable and must be estimated. A case study of volatile organic compound releases during extrusion-based additive manufacturing is used here to explore the viability of various regression methods for predicting chemical releases to inform chemical assessments.

View Article and Find Full Text PDF

Introduction: Capacity-building interventions for health extension workers (HEWs) are key to providing quality health services to the community. Since Ethiopia's Health Extension Program was established, several types of capacity-building interventions have been developed to build HEW competencies. However, no comprehensive study has mapped the types of capacity-building interventions being used or the competencies targeted.

View Article and Find Full Text PDF

This study investigated the implementation and impact of fifth-generation (5G) wireless millimeter wave (mmW) technology. 5G offers significant advancements over previous generations and supports additional frequency bands, including mmW, to enhance mobile broadband with ultra-reliable, low-latency communications, supporting a high volume of diverse communications. This technology is expected to enable billions of new connections in the Internet of Things (IoT), fostering innovations in various sectors including healthcare, manufacturing, and education.

View Article and Find Full Text PDF

Importance: Environmental service workers (ESWs) have a critical role within the hospital infrastructure and are at the frontline of infection prevention. ESWs are highly trained in managing all forms of regulated waste, which includes biohazardous waste, and are responsible for the overall patient experience, janitorial work, and infection prevention. Without environmental services, patients have a 6 times greater risk of being infected by pathogens from patients who previously occupied their room.

View Article and Find Full Text PDF

Background: Proficiency in endotracheal intubation (ETI) is essential for medical professionals and its training should start at medical schools; however, large caseload may be required before achieving an acceptable success rate with direct laryngoscopy. Video laryngoscopy has proven to be an easier alternative for intubation with a faster learning curve, but its availability in medical training may be an issue due to its high market prices. We devised a low-cost 3-dimensionally printed video laryngoscope (3DVL) and performed a randomized trial to evaluate if the intubation success rate on the first attempt with this device is noninferior to a standard commercially available video laryngoscope (STVL).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?