Effects of hemolysis, lipemia, hyperbilirrubinemia, and anticoagulants in canine C-reactive protein, serum amyloid A, and ceruloplasmin assays.

Can Vet J

Department of Animal Medicine and Surgery, Faculty of Veterinary Medicine, University of Murcia, 30100 Espinardo, Murcia, Spain.

Published: July 2005

The objective of the present study was to determine the effects that hemolysis, lipemia, bilirubinemia, and anticoagulants might have on the most commonly used assays for C-reactive protein and serum amyloid A, and determination of ceruloplasmin values in dogs. Solutions of hemoglobin, lipid, and bilirubin were added to serum aliquots. Additionally, serum and plasma samples with different anticoagulants (heparin, EDTA, and citrate) were obtained from healthy dogs. Hemolysis, lipemia, and hyperbilirubinemia interfered significantly with the C-reactive protein and ceruloplasmin results, but not with those for the serum amyloid A assay. The use of anticoagulants produced significant changes in the results for the assays tested. However, the magnitude of the differences caused by the interfering substances does not appear to have an important impact on the clinical interpretation of the tests.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1168879PMC

Publication Analysis

Top Keywords

hemolysis lipemia
12
c-reactive protein
12
serum amyloid
12
effects hemolysis
8
protein serum
8
serum
5
lipemia hyperbilirrubinemia
4
anticoagulants
4
hyperbilirrubinemia anticoagulants
4
anticoagulants canine
4

Similar Publications

Objectives: Autoverification increases the efficiency of laboratories. Laboratories accredited according to ISO 15189:2022 need to validate their processes, including autoverification, and assess the associated risks to patient safety. The aim of this study was to propose a systematic verification algorithm for autoverification and to assess its potential risks.

View Article and Find Full Text PDF

Objectives: This study examined the comparability of venous and capillary blood samples with regard to routine chemistry analytes.

Methods: Venous and capillary blood samples were collected from adult patients to assess comparability of alanine transaminase, albumin, alkaline phosphatase, apolipoprotein B, aspartate aminotransferase, total bilirubin, calcium, chloride, creatin kinase, creatinine, C-reactive protein, ferritin, folic acid, free T4, gamma glutamyltransferase, glucose, high density lipoprotein cholesterol, iron, lipase, lipoprotein a, magnesium, phosphate, postassium, prostate specific antigen, sodium, total cholesterol, total protein, transferrin, triglycerides, thyroid stimulating hormone, urate, urea, vitamin B12 and 25-hydroxyvitamin-D3. Furthermore, hemolysis-icterus-lipemia Index (HIL-Index) was measured for all samples.

View Article and Find Full Text PDF

Hemostatic function, immunomodulatory capacity, and effects of lipemia in cold-stored whole blood.

Transfusion

November 2024

Research and Development, Australian Red Cross Lifeblood, Alexandria, New South Wales, Australia.

Background: Whole blood (WB) is increasingly being used for resuscitation of trauma patients. Although platelet-, red blood cell (RBC)- and plasma-specific parameters in cold-stored WB are well characterized, there has been limited investigation of biological response modifiers (BRMs), which may induce adverse reactions in recipients. The aim of this study was to evaluate the quality and function of RBC, platelets, plasma proteins, and BRMs in cold-stored WB during storage.

View Article and Find Full Text PDF

The erythrocyte sedimentation rate (ESR) is a widely used diagnostic test, influenced by all physiological and pathological conditions that can bias blood rheology by interfering factors. This study aimed to evaluate the performance of the CUBE 30 touch ESR analyzer in samples with preanalytical variables, as lipemia, hemolysis, and icterus or in presence of fibrinogen., Moreover we focused to define the maximum time limits to ensure a reliable ESR measure.

View Article and Find Full Text PDF

Detecting IgE sensitizations in the serum of allergic dogs is commonly performed using allergen extracts, but these are difficult to standardize. This article details the development and validation of the Pet Allergy Xplorer (PAX; Nextmune, Stockholm, Sweden), the first multiplex macroarray for the detection of IgE sensitization in dogs using allergen extracts and molecular components; the PAX is derived from the Allergy Xplorer (ALEX; MacroArray Diagnostics, Vienna, Austria). The selection of allergens, cartridge processing, strategy for identifying and blocking IgE directed against cross-reactive carbohydrate determinants (CCDs), and the method used for determining the positivity threshold are described.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!