Purpose: Autoimmune Inner Ear Disease (AIED) is an idiopathic progressive, often bilateral, sensironeural hearing loss that occurs over weeks to months, generally resulting in significant auditory disability. Response to treatment with immunomodulators other than corticosteroids has been poor. Data from a guinea pig model of AIED and a recent open label trial of etanercept suggested potential treatment benefit. Based on these preliminary results, we conducted a pilot placebo controlled trial of etanercept in AIED patients.
Methods: Twenty AIED patients were enrolled in a 12-week blinded placebo (PLA) controlled randomized clinical trial of etanercept (ETA) with 25 mg SC twice weekly. Patients received treatment for 8 weeks with a 4-week follow-up off-treatment. The primary study endpoint was an improvement in pure tone threshold (PTA) of 10 Db in two consecutive frequencies and/or improvement in speech discrimination of >12% at week 8.
Results: Patient demographics were similar for the ETA and PLA patients. Seventeen subjects (8 ETA, 9 PLA) completed the trial. The 3 dropouts were due to lack of efficacy. One ETA and 2 PLA subjects achieved the primary endpoint (p > 0.999). One ETA and 1 PLA pt demonstrated improved in hearing loss and vertigo severity by VAS and hearing disability. No safety issues were observed.
Conclusion: The results of this pilot trial demonstrate that etanercept 25 mg twice weekly for 8 weeks was no better than placebo for treatment of AIED in this patient population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.mao.0000185082.28598.87 | DOI Listing |
Ann Phys Rehabil Med
January 2025
Department of Stomatology, The 960th Hospital of People's Liberation Army of China (PLA), Jinan, Shandong, 250031, China. Electronic address:
Background: Although there is increasing emphasis on rehabilitation training after ligament reconstruction, little is known about the pain induced by the procedure itself. Procedural success may be limited by pain and anxiety. Nitrous oxide is widely used to alleviate procedural pain.
View Article and Find Full Text PDFNutrients
December 2024
Departamento de Ciencias Biomédicas, Área de Educación Física y Deportiva, Facultad de Medicina y Ciencias de la Salud, Universidad de Alcalá, 28801 Madrid, Spain.
Caffeine and sodium bicarbonate individually enhance muscular endurance by delaying fatigue, but their combined effects have scarcely been studied. : This study aimed to evaluate the acute effects of co-ingesting caffeine and sodium bicarbonate on muscular endurance at different loads in bench press and back squat exercises. : Twenty-seven recreationally trained participants (female/male: 14/14; age: 23 ± 3.
View Article and Find Full Text PDFInt J Biol Macromol
November 2024
Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022, PR China; School of Applied Chemistry and Engineering, University of Science and Technology of China, Hefei 230026, PR China.
The lower melt strength of poly(lactide) (PLA) limits its broader applications. Here, a strategy combining copolymerization with multi-arm branching was propose to enhance the melt strength of PLA. Initially, stereoisomeric cyclic ester monomers (CEM) synthesized via zeolite catalysis were copolymerized into PLA chains.
View Article and Find Full Text PDFJ Sci Med Sport
September 2024
Department of Physiology and Biochemistry, Poznan University of Physical Education, Poland.
Objectives: This study quantified blood bicarbonate (HCO) kinetics and gastrointestinal upset to determine the gender-related ergogenic potential of sodium bicarbonate (0.15-, 0.25- and 0.
View Article and Find Full Text PDFSports Biomech
June 2024
M2S Laboratory (Movement, Sport & Health), University Rennes 2, ENS Rennes, Bruz, France.
This study aims to profile biomechanical abilities during sprint front crawl by identifying technical stroke characteristics, in light of performance level. Ninety-one recreational to world-class swimmers equipped with a sacrum-worn IMU performed 25 m all-out. Intra and inter-cyclic 3D kinematical variabilities were clustered using a functional double partition model.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!