Uterine perforation is one of the serious complications associated with use of the intrauterine contraceptive device (IUD). Uterine perforation by IUD can involve several neighboring organs. A case of acute appendicitis was caused by a Multiload Cu 375 IUD inserted previously. This is a rare complication and only fourteen previous cases were recorded in the literature.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4622824 | PMC |
http://dx.doi.org/10.3748/wjg.v11.i34.5414 | DOI Listing |
BMJ Glob Health
January 2025
School of Public Health and Preventive Medicine, Monash University, Melbourne, Victoria, Australia
Background: The way that healthcare services are organised and delivered (termed 'healthcare delivery arrangements') is a key aspect of a health system. Changing the way health care is delivered, for example, task shifting that delivers the same care at lower cost, may be one way of improving healthcare system sustainability. We synthesised the existing randomised trial evidence to compare the effects of alternative healthcare delivery arrangements versus usual care in Nepal.
View Article and Find Full Text PDFAJOG Glob Rep
February 2025
Department of Obstetrics and Gynecology, University of Rochester Medical Center, University of Rochester School of Medicine and Dentistry, Rochester, NY (Leubner, Levandowski, Mikami, and Betstadt).
Background: Postpartum contraception is typically provided during postpartum visits. When desired and accessible, the immediate postpartum period provides an additional opportunity to increase the use of more effective contraceptive methods to potentially reduce subsequent unintended pregnancies and improve pregnancy outcomes. In New York State, recent policy changes expanded Medicaid coverage to include immediate postplacental intrauterine device insertion.
View Article and Find Full Text PDFBMC Womens Health
December 2024
Department of Obstetrics and Gynecology, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia.
Introduction: IUDs are effective, reversible and safe methods of contraception. The mechanism of action of IUDs as a group is inducing endometrial atrophy, apoptosis, altering tubal motility; preventing sperm permeability, fertilization, and implantation. Complications of IUD include menstrual disturbance, pelvic pain, and increased risk of ectopic pregnancy with contraceptive failure, device expulsion, uterine perforation or transmural migration with misplacement of the device.
View Article and Find Full Text PDFInfect Dis Rep
December 2024
Microbial Biotechnology Laboratory, Department of Marine Biotechnology, Bharathidasan University, Tiruchirappalli 620024, India.
Indwelling intrauterine contraceptive devices (IUDs) have surfaces that facilitate the attachment of spp., creating a suitable environment for biofilm formation. Due to this, vulvovaginal candidiasis (VVC) is frequently linked to IUD usage, necessitating the prompt removal of these devices for effective treatment.
View Article and Find Full Text PDFJ Surg Case Rep
January 2025
Cork University Hospital, Wilton, Cork, T12 DC4A, Republic of Ireland.
We describe the case of a 43-year-old woman presented with an 8-month history of intermittent non-specific abdominal pain. She had an Intrauterine Contraceptive Device (IUCD) inserted 4-years ago and the device was still in-situ. After initial gynaecological assessment, further clinical radiological investigations, computerized tomography imaging showed that the intraluminal part of the radiological foreign body was seen to be possibly perforating the sigmoid colon after having migrated.