A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A prospective multicentre registry of the procedural and long-term clinical and angiographic results of stent implantation using a Dylyn coated coronary stent system. | LitMetric

Objectives: A prospective registry was performed to evaluate the safety and efficacy of a Dylyn coated coronary stent.

Background: Diamond-like nanocomposite (Dylyn) stent coating is thought to be biocompatible, resulting in decreased thrombogenicity and decreased neointimal hyperplasia.

Methods: In a multicentre, open, prospective, clinical and angiographical registry, the Dylyn-coated stent system was evaluated in patients requiring percutaneous coronary intervention. The primary procedural and angiographical endpoint of the study was the sustained success of stent-implantation using a follow-up catheterisation at six months. The primary clinical endpoint of the study was the composite incidence of death, non-fatal myocardial infarction and revascularisation at six months after stent implantation.

Results: 127 Dylyn coated coronary stents were implanted in 121 patients. Procedural success was obtained in 100% of the cases. No episodes of acute stent thrombosis occurred. The number of patients within stent restenosis at six months was 29 (24%). The primary procedural, angiographical endpoint was achieved in 91 (70%) patients. The clinical results at six-month follow-up were favourable with a MACE-rate of 7.4%.

Conclusions: A Dylyn coated coronary stent system is well tolerated and has excellent short-term results. The amount of angiographic restenosis at 6 months, however, is considerable, but comparable to other non-drug-eluting stent systems.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14628840310030450DOI Listing

Publication Analysis

Top Keywords

dylyn coated
16
coated coronary
16
stent system
12
stent
9
coronary stent
8
primary procedural
8
procedural angiographical
8
angiographical endpoint
8
endpoint study
8
restenosis months
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!