A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reproducibility of low galactomannan enzyme immunoassay index values tested in multiple laboratories. | LitMetric

The Platelia galactomannan enzyme immunoassay is a commercially available nonculture method for diagnosing invasive aspergillosis. Recently, steps have been taken to improve sensitivity; specifically, a low (0.5 to 0.7) galactomannan index (GMI) value to determine positivity has been validated by multiple groups. We evaluated the intra-assay and interassay reproducibility at low index levels using three different kit lots on three different days in three different microbiology laboratories. Clinical and spiked sera were blinded and sent with galactomannan enzyme immunoassay (EIA) kits to the participating laboratories. We also prospectively collected data on all galactomannan EIAs performed between 1 September 2003 and 21 July 2004 at the University of Washington Medical Center microbiology laboratory to assess reproducibility of clinical samples analyzed in "real time." From the multilaboratory study, a total of 836 results were available for evaluation. Reproducibility was excellent between laboratories and on different days. Significant variability was seen between runs/lots, which may in part be associated with different threshold control values in different kits. Among the 1,410 clinical samples that were prospectively analyzed, 168 (90%) were confirmed to be positive on repeat testing (GMI, > or =0.5). Among the 19 (10.2%) initially positive samples not confirmed on repeat testing, the majority had a GMI at the threshold of the assay (between 0.5 and 0.7). Our findings suggest that the Platelia galactomannan immunoassay has good reproducibility. However, changes in GMI levels when different kit lots are used, and single samples with low-positive (GMI of 0.5 to 0.7) indices, should be interpreted with caution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1234072PMC
http://dx.doi.org/10.1128/JCM.43.9.4796-4800.2005DOI Listing

Publication Analysis

Top Keywords

galactomannan enzyme
12
enzyme immunoassay
12
reproducibility low
8
low galactomannan
8
platelia galactomannan
8
kit lots
8
clinical samples
8
repeat testing
8
galactomannan
6
reproducibility
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!