A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical utility of commercial enzyme immunoassays during the inaugural season of West Nile virus activity, Alberta, Canada. | LitMetric

AI Article Synopsis

  • West Nile Virus (WNV) has become widespread in North America, prompting the need for effective laboratory testing, particularly through IgM capture enzyme immunoassays (EIA) that became available in 2003.
  • A study in Alberta tested nearly 3,000 samples, identifying 266 WNV cases, finding that sensitivity of the assays improved significantly after the first week of illness, reaching up to 97% after day 8.
  • The Focus IgM EIA showed high specificity (98.9%), while the first-generation Panbio had lower specificity (82.9%); both tests were effective for diagnosing WNV when follow-up samples were taken after 8 days.

Article Abstract

West Nile virus (WNV) has spread rapidly across North America, creating a need for rapid and accurate laboratory diagnosis on a large scale. Immunoglobulin M (IgM) capture enzyme immunoassays (EIA) became commercially available in the summer of 2003, but limited data are available on their clinical performance. Consolidated human WNV diagnostic testing for the province of Alberta, Canada, at the public health laboratory permitted a large-scale evaluation of the assays, covering a wide clinical spectrum. Two thousand nine hundred sixty-nine sera were tested, from 2,553 Alberta residents, and 266 cases were identified. Sensitivities of the Focus assay and first-generation Panbio IgM capture EIA were 79 and 80%, respectively. During the first week of illness only 53 to 58% of cases were positive, but sensitivity was 96 to 97% after day 8. Sensitivity for neurological cases was 92% overall. Specificity was high for the Focus kit at 98.9%, but only 82.9% for the first Panbio kit. A positive Focus WNV IgG result with a twofold rise in IgG index was a reliable indicator of acute flavivirus infection (67/67 WNV). Agreement between the IgG test and hemagglutinin inhibition titers in paired sera was at least 82%. Commercial IgM and IgG EIA proved useful for WNV diagnosis, provided follow-up sera were collected after 8 days of illness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1234144PMC
http://dx.doi.org/10.1128/JCM.43.9.4691-4695.2005DOI Listing

Publication Analysis

Top Keywords

enzyme immunoassays
8
west nile
8
nile virus
8
alberta canada
8
igm capture
8
wnv
5
clinical utility
4
utility commercial
4
commercial enzyme
4
immunoassays inaugural
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!