Assessment of intraluminal impedance for the detection of pharyngeal bolus flow during swallowing in healthy adults.

Am J Physiol Gastrointest Liver Physiol

Department of Paediatrics, University of Adelaide, and Centre for Paediatric and Adolescent Gastroenterology, Women's and Children's Hospital, Adelaide, South Australia.

Published: January 2006

Intraluminal impedance, a nonradiological method for assessing bolus flow within the gut, may be suitable for investigating pharyngeal disorders. This study evaluated an impedance technique for the detection of pharyngeal bolus flow during swallowing. Patterns of pharyngoesophageal pressure and impedance were simultaneously recorded with videofluoroscopy in 10 healthy volunteers during swallowing of liquid, semisolid, and solid boluses. The timing of bolus head and tail passage recorded by fluoroscopy was correlated with the timing of impedance drop and recovery at each recording site. Bolus swallowing produced a drop in impedance from baseline followed by a recovery to at least 50% of baseline. The timing of the pharyngeal and esophageal impedance drop correlated with the timing of the arrival of the bolus head. In the pharynx, the timing of impedance recovery was delayed relative to the timing of clearance of the bolus tail. In contrast, in the upper esophageal sphincter (UES) and proximal esophagus, the timing of impedance recovery correlated well with the timing of clearance of the bolus tail. Impedance-based estimates of pharyngoesophageal bolus clearance time correlated with true pharyngoesophageal bolus clearance time. Patterns of intraluminal impedance recorded in the pharynx during bolus swallowing are therefore more complex than those in the esophagus. During swallowing, mucosal contact between the tongue base and posterior pharyngeal wall prolongs the duration of pharyngeal impedance drop, leading to overestimation of bolus tail timing. Therefore, we conclude that intraluminal impedance measurement does not accurately reflect the bolus transit in the pharynx but does accurately reflect bolus transit across the UES and below.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpgi.00011.2005DOI Listing

Publication Analysis

Top Keywords

intraluminal impedance
16
bolus
14
impedance
12
bolus flow
12
timing impedance
12
impedance drop
12
bolus tail
12
timing
9
detection pharyngeal
8
pharyngeal bolus
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!