A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement. | LitMetric

Background: Glenoid loosening continues to be the primary reason for failure of total shoulder arthroplasty. The purpose of this study was to evaluate, with use of a sensitive and reproducible imaging method, the radiographic and clinical results of total shoulder replacement with a pegged, cemented polyethylene glenoid implant.

Methods: Forty-three patients (forty-seven shoulders) underwent a total shoulder replacement with a cemented polyethylene glenoid component with four threaded pegs. The patients were examined clinically, with fluoroscopically guided radiographs, and with computed tomography at an average of forty months. In addition to conventional scoring of radiographic lucency, an 18-point scoring system was used to quantify cement-peg lucencies in six zones of the back surface of the glenoid component as seen on computed tomography scans.

Results: On the average, the absolute Constant score improved from 39 points preoperatively to 70 points at the time of follow-up (p = 0.0001) and the pain score improved from 5 to 13 points (p = 0.001). The mean active anterior elevation improved by 34 degrees (p = 0.001) and the mean abduction, by 46 degrees (p = 0.006). Two patients had symptomatic glenoid loosening requiring revision. Twenty-one of the forty-seven shoulders had radiographic lucency around the glenoid pegs, and nine had progression of the lucency by at least two grades. Computed tomography detected lucencies, primarily at the bone-cement interface, in thirty-six shoulders. The scores for the lucencies seen on the computed tomography scans were associated with the radiographic lucency scores (p < 0.001), pain scores (p = 0.04), and abduction strength (p = 0.02). Computed tomography was more sensitive than radiography with regard to identifying the number of pegs associated with lucency and the size of the lucencies. The overall reproducibility of the scoring based on the computed tomography was higher than that of the radiographic scoring.

Conclusions: Computed tomography provided a more sensitive and reproducible tool for the assessment of loosening of pegged glenoid components than did fluoroscopically guided conventional radiography. Further improvement in implant design and fixation technique appears to be necessary for long-term success of cemented glenoid components.

Download full-text PDF

Source
http://dx.doi.org/10.2106/JBJS.D.02675DOI Listing

Publication Analysis

Top Keywords

computed tomography
32
total shoulder
16
polyethylene glenoid
12
glenoid components
12
shoulder replacement
12
radiographic lucency
12
glenoid
9
tomography
8
glenoid loosening
8
sensitive reproducible
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!