Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation.

Intensive Care Med

Département d'Anesthésie Réanimation A, Hôpital Lapeyronie, Montpellier, France.

Published: July 1992

Inspired gases must be warmed and humidified during mechanical ventilation. In a prospective randomized study we compared the performance of a heated humidifier (HH) (Draegger Aquaport) and a heat and moisture exchanger (HME) (Pall Filter BB 2215). A total of 116 patients requiring mechanical ventilation (Servo 900 C Siemens) were enrolled into the study and were randomly assigned to 2 groups. Patients in group I were ventilated with a traditional breathing circuit with HH and patients in group II using a simplified circuit with HME. Pre-existing and hospital acquired atelectasis and pneumonia, occurrence of endotracheal tube (ET) occlusion and ventilatory parameters (respiratory rate, tidal volume) were studied. No statistical difference was found between groups for each parameter except the greater frequency of ET occlusions in the II group (0/61 vs 9/55) (p = 0.0008). Pall Filter (PF), a hydrophobic filter, humidifies the dry gases from the condensed water which is put down on the HME surfaces during cooling of saturated expired gases. This purely physical property is linked to the magnitude of the thermic gradient between the expired gases and the ambiant temperature. Performance impairment of PF in our study might be due to high ambiant temperature in the intensive care unit (usually around 28 degrees C) which reduces thermic gradient and water exchanges. We conclude that efficiency of PF may be weak in some conditions of ambiant temperature.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF01705040DOI Listing

Publication Analysis

Top Keywords

mechanical ventilation
12
ambiant temperature
12
heat moisture
8
heated humidifier
8
pall filter
8
patients group
8
expired gases
8
thermic gradient
8
comparison hydrophobic
4
hydrophobic heat
4

Similar Publications

Effectiveness of Using Checklist in Preventing Facial, Nasal and Head Pressure Injuries in Preterm Infants in Nasal Noninvasive Mechanic Ventilation: A Quasi-Experimental Study.

J Perinat Neonatal Nurs

October 2024

Author Affiliations: Department of Child Health and Diseases Nursing (Dr Güner Başara), Faculty of Health Sciences, Gaziosmanpaşa University, Tokat, Turkey; and Department of Child Health and Diseases Nursing, Faculty of Nursing (Dr Çalışır), Department of Neonatology, Faculty of Medicine (Dr Kaynak Türkmen, retired), Aydın Adnan Menderes University, Aydın, Turkey.

Background: Noninvasive mechanical ventilation (NIMV), when in synchronized intermittent mandatory ventilation, continuous positive airway pressure, or patient-triggered ventilation modes, is known to be a cause of facial, nasal, head, and skin pressure injuries in preterm infants.

Objective: The objective of this study is to examine the efficacy of using a checklist with preterm infants under nasal NIMV in preventing facial, nasal, and head pressure injuries.

Method: The study was conducted quasi-experimentally on preterm infants under NIMV.

View Article and Find Full Text PDF

Pulmonary surfactant (PS) is one of the main treatment for neonates with respiratory distress syndrome (RDS). Budesonide has recently been studied as an additional treatment in such cases, but there is limited evidence supporting this. This study was implemented to determine the efficacy of PS combined with budesonide in premature infants.

View Article and Find Full Text PDF

Unplanned extubation (UPE), defined as accidental removal of the endotracheal tube during mechanical ventilation or its replacement due to suspected obstruction or inadequate diameter, is considered the fourth most common adverse event in neonatal intensive care units (NICU). This study aimed to describe a systematic review and meta-analysis protocol that will identify and assess the effect of primary intervention measures designed to prevent UPE in NICU. A search will be carried out in the following databases: PubMed/Medline, EMBASE, Scopus, CINAHL, Cochrane Library, SciELO, and LILACS.

View Article and Find Full Text PDF

Using Implementation Science to Assess Barriers to Agreement on Sedation Goal Setting and Assessment.

Pediatr Crit Care Med

January 2025

Perioperative & Critical Care-Center for Outcomes Research and Evaluation (PC-CORE), Boston Children's Hospital, Boston, MA.

Objectives: Sedation assessment and goal setting using a validated assessment tool are key components of the ICU Liberation bundle. Appropriate integration of these bundle elements into daily practice remains challenging. Understanding barriers is an important step toward implementation of these best practice bundle elements.

View Article and Find Full Text PDF

Background: Patients with sepsis frequently require invasive mechanical ventilation. How oxygenation during mechanical ventilation affects clinical outcomes for patients with sepsis remains uncertain.

Research Question: To evaluate the effects of different oxygen saturation targets on clinical outcomes for patients with sepsis receiving mechanical ventilation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!