In this study, the separation of biologically active peptides on two zirconia-based phases, polybutadiene (PBD)-ZrO2 and polystyrene (PS)-ZrO2, and a silica-based phase C18 was compared. Basic differences in interactions on both types of phases led to quite different selectivity. The retention characteristics were investigated in detail using a variety of organic modifiers, buffers, and temperatures. These parameters affected retention, separation efficiency, resolution and symmetry of peaks. Separation systems consisting of Discovery PBD-Zr column and mobile phase composed of a mixture of acetonitrile and phosphate buffer, pH 2.0 (45:55, v/v) at 70 degrees C and Discovery PS-Zr with acetonitrile and phosphate buffer, pH 3.5 in the same (v/v) ratio at 40 degrees C were suitable for a good resolution of enkephalin related peptides. Mobile phase composed of acetonitrile and phosphate buffer, pH 5.0 (22:78, v/v) was appropriate for separation of enkephalins on Supelcosil C18 stationary phase.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2005.01.058 | DOI Listing |
Sci Rep
January 2025
Pharmaceutical Chemistry Department, Faculty of Pharmacy, Horus University, New Damietta, 34517, Egypt.
RP-HPLC technique was developed and optimized for simultaneous identification and estimation of nirmatrelvir (NIR) and ritonavir (RIT) in their new copackaged tablet. Stability of nirmatrelvir (NIR) was studied after exposure to different five stress conditions; alkali, acid, heat, photo and oxidation degradation. The chromatographic separation was achieved using VDSpher PUR 100 ODS (4.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
January 2025
Hacettepe University, Faculty of Pharmacy, Department of Pharmaceutical Technology, Ankara 06100 Türkiye. Electronic address:
A new reversed phase high-performance liquid chromatography (RP-HPLC) method, with a short analysis time and easy to apply, was developed for the simultaneous detection of cimetidine (CIM), metoprolol tartrate (MT) and phenol red (PR) for use in intestinal perfusion studies. The analysis was performed with phosphate buffer (pH 5.0, 12.
View Article and Find Full Text PDFJ Chromatogr A
December 2024
HUN-REN Molecular Interactions in Separation Science Research Group, Ifjúság útja 6, H-7624 Pécs, Hungary; Department of Analytical and Environmental Chemistry and Szentágothai Research Center, University of Pécs, Ifjúság útja 6, H-7624 Pécs, Hungary; Institute of Bioanalysis, Medical Scool, University of Pécs, Szigeti út, H-7624 Pécs, Hungary. Electronic address:
Non-destructive chromatographic methods were used to determine the hold-up volumes of four self-packed columns containing embedded phosphate groups. The stationary phases are named Diol-P-C10, Diol-P-C18, Diol-P-Benzyl and Diol-P-Chol. The hydrophobicity of organic ligands bound to the phosphate group increases in the benzyl< decyl < octadecyl
Sci Rep
January 2025
Egyptian Drug Authority (EDA), Giza, 35521, Egypt.
Angew Chem Int Ed Engl
December 2024
Jiangsu Key Laboratory of Materials and Technologies for Energy Storage Technology, College of Material Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu, 210016, People's Republic of China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!