Purpose: To prospectively compare the sensitivity and specificity of unenhanced low-dose multi-detector row computed tomography (CT) with those of contrast material-enhanced standard-dose multi-detector row CT in patients suspected of having acute diverticulitis.

Materials And Methods: Institutional review board approval and informed consent were obtained. One hundred ten consecutive patients (40 men, 70 women; age range, 30-82 years; mean, 57 years) suspected of having acute diverticulitis underwent unenhanced multi-detector row CT with 4 x 2.5-mm collimation, 120 kVp, and 30 effective mAs, as well as contrast-enhanced standard-dose multi-detector row CT with the same parameters but with 120 mAs. All scans were independently read by four readers. Intra- and interobserver agreements were calculated with the kappa statistic. Contrast-enhanced standard-dose scans read by three other experts and considered together with results from colonoscopy, surgery, and pathologic evaluation were used as reference. Differences in sensitivity and specificity between readers, radiation doses, and reading sessions were investigated. Pearson exact test and logistic regression models were used.

Results: Colon diverticulitis was present in 39 patients (34%) and was graded as mild in 22 patients (56%) and severe in 17 (44%). Agreement within and between readers was good to excellent. No significant difference was observed in sensitivity (P ranging from .081 to >.99) or in specificity (P ranging from .326 to >.99) for any sign or overall diagnosis between radiation doses by all readers, except wall thickening, which for one reader had a higher specificity at low dose than at standard dose (P = .025). No significant difference in misclassification was detected between doses, regardless of the reader (P ranging from .481 to >.99). At both doses, the most predictive sign for acute diverticulitis was retroperitoneal fat stranding (P < .001).

Conclusion: Low-dose unenhanced multi-detector row CT has a diagnostic performance similar to that of contrast-enhanced standard-dose multi-detector row CT in patients suspected of having acute diverticulitis.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2371041432DOI Listing

Publication Analysis

Top Keywords

multi-detector row
28
suspected acute
16
unenhanced multi-detector
12
standard-dose multi-detector
12
acute diverticulitis
12
contrast-enhanced standard-dose
12
colon diverticulitis
8
low-dose unenhanced
8
sensitivity specificity
8
row patients
8

Similar Publications

Objectives: Primary pulmonary artery sarcoma (PPAS) is a rare disease with unclear clinical manifestations. Advances in imaging devices have improved diagnostic capabilities, potentially affecting clinical characteristics and overall survival (OS); however, details remain unclear. This study conducted a pooled analysis of case reports and series to analyse the clinical characteristics and OS of PPAS in the era of advanced medical devices.

View Article and Find Full Text PDF

Improvement of image quality of dentomaxillofacial region in ultra-high resolution computed tomography: A phantom study.

Dentomaxillofac Radiol

November 2024

Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3‑1‑1 Maidashi, Higashi‑ku, Fukuoka, 812‑8582, Japan.

Objectives: The purpose of this study was to compare the image quality of ultra-high-resolution computed tomography (U-HRCT) with that of conventional multi-detector row CT (convCT) and demonstrate its usefulness in the dentomaxillofacial region.

Methods: Phantoms were helically scanned with U-HRCT and convCT scanners using clinical protocols. In U-HRCT, phantoms were scanned in super-high-resolution (SHR) mode, and hybrid iterative reconstruction (HIR) and filtered-back projection (FBP) techniques were performed using a bone kernel (FC81).

View Article and Find Full Text PDF

Background: Peripheral arterial disease (PAD) of the lower limbs is caused by atherosclerotic occlusive disease in which narrowing of arteries reduces blood flow to the lower limbs. PAD is common; it is estimated to affect 236 million individuals worldwide. Advanced age, smoking, hypertension, diabetes and concomitant cardiovascular disease are common factors associated with increased risk of PAD.

View Article and Find Full Text PDF

A retrieval of relevant literature on hepatic nodular lesions, gastric cancer (GC), and Crohn's disease (CD) was conducted from Chinese and English databases. Meta-analysis was performed using Review Manager 5.4 software and the MIDAS package in Stata 18.

View Article and Find Full Text PDF

Objectives: To assess the relationships between longitudinal fluoride intakes and bone densitometry outcomes in young adults.

Methods: Data were analyzed from the Iowa Fluoride Study and Iowa Bone Development Study, which followed 1,882 infants from birth in 1992. Daily fluoride intakes were assessed using detailed questionnaires sent every 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!