Forensic and clinical laboratories benefit from DNA standard reference materials (SRMs) that provide the quality control and assurance that their results from sequencing unknown samples are correct. Therefore, the mitochondrial DNA (mtDNA) genome of HL-60, a promyelocytic leukemia cell line, has been completely sequenced by four laboratories and will be available to the forensic and medical communities in the spring of 2003; it will be called National Institute of Standards and Technology (NIST) SRM 2392-I. NIST human mtDNA SRM 2392 will continue to be available and includes the DNA from two apparently healthy individuals. Both SRM 2392 and 2392-I contain all the information (e.g. the sequences of 58 unique primer sets) needed to use these SRMs as positive controls for the amplification and sequencing any DNA. Compared to the templates in SRM 2392, the HL-60 mtDNA in SRM 2392-I has two tRNA differences and more polymorphisms resulting in amino acid changes. Four of these HL-60 mtDNA polymorphisms have been associated with Leber Hereditary Optic Neuropathy (LHON), one as an intermediate mutation and three as secondary mutations. The mtDNA from a cell line (GM10742A) from an individual with LHON was also completely sequenced for comparison and contained some of the same LHON mutations. The combination of these particular LHON associated mutations is also found in phylogenetic haplogroup J and its subset, J2, and may only be indicative that HL-60 belongs to haplogroup J, one of nine haplogroups that characterize Caucasian individuals of European descent or may mean that haplogroup J is more prone to LHON. Both these mtDNA SRMs will provide enhanced quality control in forensic identification, medical diagnosis, and single nucleotide polymorphism detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S1567-7249(03)00010-2DOI Listing

Publication Analysis

Top Keywords

srm 2392
12
mtdna genome
8
leber hereditary
8
hereditary optic
8
optic neuropathy
8
nist human
8
mitochondrial dna
8
dna standard
8
standard reference
8
quality control
8

Similar Publications

Standard Reference Materials SRM 2392 and 2392-I are intended to provide quality control when amplifying and sequencing human mitochondrial genome sequences. The National Institute of Standards and Technology (NIST) offers these SRMs to laboratories performing DNA-based forensic human identification, molecular diagnosis of mitochondrial diseases, mutation detection, evolutionary anthropology, and genetic genealogy. The entire mtGenome (∼16569bp) of SRM 2392 and 2392-I have previously been characterized at NIST by Sanger sequencing.

View Article and Find Full Text PDF

Massively parallel pyrosequencing of the mitochondrial genome with the 454 methodology in forensic genetics.

Forensic Sci Int Genet

September 2014

Section of Forensic Genetics, Department of Forensic Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Frederik V's Vej 11, DK-2100 Copenhagen Ø, Denmark. Electronic address:

of sequencing of whole mitochondrial genome, HV1 and HV2 DNA with the second generation system (SGS) Roche 454 GS Junior were compared with results of Sanger sequencing and SNP typing with SNaPshot single base extension detected with MALDI-TOF and capillary electrophoresis. We investigated the performance of the software analysis of the data, reproducibility, ability to sequence homopolymeric regions, detection of mixtures and heteroplasmy as well as the implications of the depth of coverage. We found full reproducibility between samples sequenced twice with SGS.

View Article and Find Full Text PDF

Forensic and clinical laboratories benefit from DNA standard reference materials (SRMs) that provide the quality control and assurance that their results from sequencing unknown samples are correct. Therefore, the mitochondrial DNA (mtDNA) genome of HL-60, a promyelocytic leukemia cell line, has been completely sequenced by four laboratories and will be available to the forensic and medical communities in the spring of 2003; it will be called National Institute of Standards and Technology (NIST) SRM 2392-I. NIST human mtDNA SRM 2392 will continue to be available and includes the DNA from two apparently healthy individuals.

View Article and Find Full Text PDF

The Standard Reference Materials Program at the US National Institute of Standards and Technology (NIST) has three human DNA standard reference materials (SRM 2390, SRM 2391a, and SRM 2392) currently available [1, 2]. Both the DNA profiling SRM 2390 and the polymerase chain reaction (PCR)-based DNA profiling SRM 2391a are intended for use in forensic and paternity identifications, for instructional law enforcement, or for non-clinical research purposes and are not intended for clinical diagnostics. The mitochondrial DNA (mtDNA) SRM 2392 is to provide standardization and quality control when performing PCR and sequencing any segment or the entire 16,569 base pairs that comprise human mitochondrial DNA.

View Article and Find Full Text PDF