Simultaneous recording of event-related electroencephalographic (EEG) and functional magnetic resonance imaging (fMRI) responses has the potential to provide information on how the human brain reacts to an external stimulus with unique spatial and temporal resolution. However, in most studies combining the two techniques, the acquisition of functional MR images has been interleaved with the recording of evoked potentials. In this study we investigated the feasibility of recording pain-related evoked potentials during continuous and simultaneous collection of blood oxygen level-dependent (BOLD) functional MR images at 3 T. Brain potentials were elicited by selective stimulation of cutaneous Adelta and C nociceptors using brief radiant laser pulses (laser-evoked potentials, LEPs). MR-induced artifacts on EEG data were removed using a novel algorithm. Latencies, amplitudes, and scalp distribution of LEPs recorded during fMRI were not significantly different from those recorded in a control session outside of the MR scanner using the same equipment and experimental design. Stability tests confirmed that MR-image quality was not impaired by the evoked potential recording, beyond signal loss related to magnetic susceptibility differences local to the electrodes. fMRI results were consistent with our previous studies of brain activity in response to nociceptive stimulation. These results demonstrate the feasibility of recording reliable pain-related LEPs and fMRI responses simultaneously. Because LEPs collected during fMRI and those collected in a control session show remarkable similarity, for many experimental designs the integration of LEP and fMRI data collected in separate, single-modality acquisitions may be appropriate. Truly simultaneous recording of LEPs and fMRI is still desirable in specific experimental conditions, such as single-trial, learning, and pharmacological studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.neuroimage.2005.06.060DOI Listing

Publication Analysis

Top Keywords

simultaneous recording
12
brain potentials
8
potentials continuous
8
functional magnetic
8
magnetic resonance
8
resonance imaging
8
fmri responses
8
functional images
8
evoked potentials
8
feasibility recording
8

Similar Publications

Multi-level encoding of reward, effort, and choice across the frontal cortex and basal ganglia during cost-benefit decision-making.

Cell Rep

January 2025

Medical Research Council Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK. Electronic address:

Adaptive value-guided decision-making requires weighing up the costs and benefits of pursuing an available opportunity. Though neurons across frontal cortical-basal ganglia circuits have been repeatedly shown to represent decision-related parameters, it is unclear whether and how this information is coordinated. To address this question, we performed large-scale single-unit recordings simultaneously across 5 medial/orbital frontal and basal ganglia regions as rats decided whether to pursue varying reward payoffs available at different effort costs.

View Article and Find Full Text PDF

This work demonstrates the feasibility of performing through-the-sensor (TTS) sub-bottom imaging using low-frequency ([100 Hz-1kHz]) self-noise generated by the propulsion of an autonomous underwater vehicle (AUV) acting as a source of opportunity. The self-noise was recorded by a short towed horizontal line array (11.4 m aperture) by the same AUV while it operated ∼35 m above the seabed along a range-dependent section at the New England shelf break.

View Article and Find Full Text PDF

Catechins in tea, as promoters of human health, have attracted widespread attention. Herein, a dual-signal mode (colorimetric and fluorescence) sensor array for catechin species fingerprinting was built based on PtNi bunched nanoparticle (PtNi-BNP)--phenylenediamine (OPD)-HO system. PtNi-BNPs catalyze the reaction between OPD and HO to produce oxidized OPD (oxOPD) with both colorimetric (yellow) and fluorescent properties.

View Article and Find Full Text PDF

This study evaluated the concurrent validity of the Vitruve linear encoder compared to the T-Force device for measuring mean propulsive velocity (MPV) and peak velocity (PV) during the free-weight bench press exercise. Thirteen resistance-trained men participated in three sessions, during which MPV and PV were recorded simultaneously by both devices. The data were analysed using one-way ANOVA, Pearson's correlation, Bland-Altman analysis, and effect size calculations, with statistical significance set at ≤ 0.

View Article and Find Full Text PDF

Background: Artificial intelligence (AI) has become widely applied across many fields, including medical education. Content validation and its answers are based on training datasets and the optimization of each model. The accuracy of large language model (LLMs) in basic medical examinations and factors related to their accuracy have also been explored.

View Article and Find Full Text PDF