Objective: There may be advantages in using magnetic resonance imaging (MRI) in small-bowel disease. The aims of this study were to optimize the MRI examination technique and to evaluate the capabilities of MRI compared with those of conventional enteroclysis (CE).

Materials And Methods: MRI and CE were performed in 36 patients suspected of Crohn's disease. Based on 26 pilot studies optimal oral administration of plum juice and bulk fibre laxative was found. T2-weighted and gadolinium enhanced T1-weighted images were obtained using a breath-holding technique and butylscopolamine. Virtual endoscopy was performed. Conventional enteroclysis entailed duodenal intubation and administration of barium and air. Two radiologists evaluated the examinations independently. Finally, each patient scored the degree of discomfort, and preference for either MRI or CE was found.

Results: The MRI technique ensured sufficient distension of the small bowel and small-bowel changes were found in 12 patients. In 3 patients this was not seen on conventional enteroclysis, which did not reveal any pathology that was not already seen on MRI. Pathological abdominal changes were found in 70% more patients during MRI than during conventional enteroclysis (p < 0.001). Endoscopic examination corresponded with the MRI findings. The examination quality decreased with increasing age (p = 0.002) and the interobserver agreement of the pathological changes was high (p < 0.001). Virtual endoscopy resulted in excellent demonstration of the mucosal surface. The examination discomfort scores obtained during the MRI were lower than those during conventional enteroclysis (p < 0.001).

Conclusions: MRI using the current technique is preferable to conventional enteroclysis because of superior demonstration of the entire small-bowel pathology, low level of patient discomfort and absence of radiation exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00365520510015683DOI Listing

Publication Analysis

Top Keywords

conventional enteroclysis
24
mri
11
magnetic resonance
8
resonance imaging
8
small bowel
8
crohn's disease
8
virtual endoscopy
8
conventional
6
enteroclysis
6
imaging small
4

Similar Publications

small bowel adenocarcinoma (SBA) in the terminal ileum is the least common of the SBA types. However, its highest prevalence is found in the presence of Crohn's disease (CD). As patients with SBA and CD present with similar symptoms, there is a high chance of misdiagnosing SBA as CD.

View Article and Find Full Text PDF

Aim: To assess the diagnostic significance of magnetic resonance enterography (MRE) and conventional enteroclysis (CE) in patients with complicated and/or advanced stage of Crohn's disease.

Methods: Patients with abnormal CE findings suggestive of mural and/or extramural involvement with the diagnosis or pre-diagnosis of CD are evaluated. After real-time bowel distension by enteroscopic examination, the patients with advanced or complicated stage were taken to the MRE examination in the same session.

View Article and Find Full Text PDF

Pilot study of endoscopic retrograde 3-dimensional - computed tomography enteroclysis for the assessment of Crohn's disease.

Eur J Radiol Open

May 2017

Division of Gastroenterology and Hematology/Oncology, Department of Medicine, Asahikawa Medical University, 2-1-1-1 Midorigaoka-Higashi, Asahikawa, Hokkaido 078-8510, Japan.

Purpose: Endoscopic retrograde ileography (ERIG) is developed in our institute and applied clinically for the diagnosis and assessment of the Crohn's disease activity. We have further improved the technique using 3-dimensional - computed tomography enteroclysis (3D-CTE) and conducted a retrospective study to determine the feasibility and the diagnostic value of endoscopic retrograde 3D-CTE (ER 3D-CTE) in Crohn's disease patients in a state of remission.

Methods: Thirteen Crohn's patients were included in this pilot study.

View Article and Find Full Text PDF

Small-bowel neoplasms are the 3%-6% of all gastrointestinal tract neoplasms. Due to the rarity of these lesions, the low index of clinical suspicion, and the inadequate radiologic examinations or incorrect interpretation of radiologic findings, a delay in diagnosis of 6-8 months from the first symptoms often occurs. Even if conventional enteroclysis and capsule endoscopy are the most common procedures used to accurately depict the bowel lumen and mucosal surface, their use in evaluating the mural and extramural extents of small-bowel tumors is limited.

View Article and Find Full Text PDF

Capsule Endoscopy for Crohn's Disease: Current Status of Diagnosis and Management.

Gastroenterol Res Pract

January 2016

Department of Internal Medicine, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Republic of Korea.

Crohn's disease (CD) is an idiopathic inflammatory bowel disease involving the small and/or large intestine. More than 50% of Western CD patients and up to 88% of Asian CD patients may have small intestinal involvement. Video capsule endoscopy (VCE) has a higher diagnostic yield than small bowel barium radiography and computed tomography enterography for the detection of small intestinal involvement of CD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!