Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Bisphenol A (BPA) is a weak estrogen. Pharmacokinetic studies of BPA have demonstrated a rapid and extensive metabolism of BPA to the nonestrogenic BPA-monoglucuronide (BPA-gluc). Some investigators have reported that BPA was found at parts per billion concentrations in the tissues or urine of humans without known exposure to BPA. This work developed a rapid and sensitive method for the determination of BPA and BPA-gluc in plasma and urine based on liquid chromatography-tandem mass spectrometry. The liquid chromatography-electrospray ionization-tandem mass spectrometry method for quantitation of BPA and BPA-gluc uses stable isotope-labeled internal standards. A linear ion trap mass spectrometer permits identification and quantitation of BPA-gluc and BPA without sample workup. Development of separation conditions reduced the BPA-background in solvent samples to below 2.5 pmol/ml for BPA. Limit of quantitation (LOQ) for BPA in control urine was 15 pmol/ml; LOQ for BPA-gluc was 65 pmol/ml. Application of the method to urine samples from human subjects (n = 6) after administration of 25 microg of BPA/person (estimated maximum human daily intake) permitted the determination of excretion kinetics for BPA-gluc; BPA was below the LOD in all except two of the samples. In urine or blood samples of human subjects (n = 19) without intentional exposure to BPA, BPA concentrations were always below the limit of detection ( approximately 2.5 pmol/ml) with or without prior glucuronidase treatment. The results show that care is required for analysis of BPA and its major metabolite BPA-gluc. The LOD obtained and the absence of detectable levels of BPA in samples from individuals suggests that general exposure of humans to BPA is much lower than the worst-case exposure scenario developed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1124/dmd.105.005454 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!