Purpose: We sought to report interocular axial length difference (IALD) between the operated eye and fellow eye at the time of pediatric cataract surgery.
Methods: A retrospective analysis of 171 cataractous (operated) eyes (mean patient age at surgery, 56.9 months; range, 0.2-230.0) was undertaken. Descriptive statistics, analysis of covariance, and regression analysis were used in statistical analysis.
Results: The mean IALD was 0.05 +/- 1.15 mm. If absolute values were used, mean IALD was 0.76 +/- 0.86. Nearly half of the subjects (48.0%) showed an IALD of >/=0.5 mm. Forty-one patients (24.0%) had operated (cataractous) eyes that were >/=0.5 mm shorter than the fellow eye, and 41 patients (24.0%) had operated eyes that were >/=0.5 mm longer than the fellow eye. The mean IALD in unilateral and bilateral cases was 0.10 +/- 1.33 and -0.03 +/- 0.76, respectively (P = 0.4). If absolute values were used, it was 0.98 +/- 0.90 and 0.40 +/- 0.65 in unilateral and bilateral cases, respectively (P < 0.001). IALD was more predictable in unilateral than in bilateral cases (P < 0.001). In unilateral cases, age at surgery (P = 0.04) and AL of the operated eye (P < 0.001) correlated with IALD. IALD did not correlate with gender, ethnicity, or type of cataract in either unilateral or bilateral cases.
Conclusions: An IALD of >/=0.5 mm occurred in 48.0% of patients with pediatric cataracts and occurred more often with unilateral cataractous patients than with bilateral cases. In patients with unilateral cataract, age at surgery and AL of the operated eye could help predict the IALD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jaapos.2005.02.009 | DOI Listing |
J Magn Reson Imaging
January 2025
Department of Radiology, The Third Affiliated Hospital of Soochow University, Changzhou, Jiangsu, China.
Background: As ferroptosis is a key factor in renal fibrosis (RF), iron deposition monitoring may help evaluating RF. The capability of quantitative susceptibility mapping (QSM) for detecting iron deposition in RF remains uncertain.
Purpose: To investigate the potential of QSM to detect iron deposition in RF.
J Feline Med Surg
January 2025
Department of Surgical & Radiological Sciences, University of California-Davis, Davis, CA, USA.
Objectives: Serum galectin-3 (sGal-3) is a protein present in renal tubules and increases in experimental rodent models of acute kidney injury. The aim of this study was to compare sGal-3 concentrations in healthy cats and cats with ureteral obstruction (UO).
Methods: This was a retrospective study.
J Perioper Pract
January 2025
San Juan Veterans Affairs Medical Center, San Juan, Puerto Rico.
Case: An active healthy 68-year-old male sustained a bilateral quadriceps tendon rupture while running. He underwent a simultaneous bilateral quadriceps tendon repair in a dual-surgeon approach. The right quadriceps tendon was repaired with a tourniquet, while the left quadriceps tendon tear was repaired without one.
View Article and Find Full Text PDFFront Neurol
January 2025
Department of Neurology, Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China.
Objective: To investigate changes of brain functional activity in patients with acute unilateral vestibulopathy (AUVP) using functional magnetic resonance imaging (fMRI).
Methods: We studied 32 AUVP patients and 30 healthy controls (HC) who received resting-state fMRI scanning. Methods of voxel-based amplitude of low-frequency fluctuation (ALFF) and seed-based functional connectivity (FC) were adopted to compare the difference in brain function between the two groups.
Aim: This study investigated the accuracy of intraoral scanner (IOS) based on different image acquisition technologies in the field of presurgical-orthopedictreatment (PSOT) in neonates with cleft.
Methods: Dental cast models of clinical situations representing unilateral cleft-lip-palate(UCLP), bilateral cleft-lippalate( BCLP) and cleft-palate(CP) with reference PEEK-scanbodies (Cares RC Mono-Scankörper, Straumann, Switzerland) were scanned utilizing four IOS systems: CareStream-CS3600®(CS), Medit-i500®(MD), Cerec-Omnicam®(SO), 3Shape-Trios-3®(TS). One calibrated operator made 5 scans from each model using each IOS (N=60).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!