Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, were compared with each other and to Goldmann applanation tonometry in a large group of healthy subjects and patients with ocular hypertension or glaucoma (n = 103). Measurements performed with the ICARE and the Tonopen XL were in good agreement with that of the Goldmann tonometer. Intraocular pressure (IOP) values measured with the TGDc-01 were significantly lower and showed more variability. The 95% limits of agreement (portable tonometer - Goldmann) were -17 to +10 mmHg for the TGDc-01, -6 to +7 mmHg for the ICARE and -6 to +8 mmHg for the Tonopen. Corneal thickness could not explain the differences between an IOP measured with the portable tonometers and an IOP measured with the Goldmann tonometer. Patient comfort was slightly higher for ICARE when compared with the Tonopen.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1475-1313.2005.00318.x | DOI Listing |
J Clin Med
October 2024
Department of Optics, Optometry and Vision Sciences, University of Valencia, 46100 Valencia, Spain.
: This study investigated intraocular pressure (IOP) changes after a blood draw in older adults considering sex, age, and baseline IOP. : Fifty-three subjects (54.7% females; age: 68.
View Article and Find Full Text PDFFront Med (Lausanne)
June 2024
Singapore National Eye Centre, Singapore, Singapore.
Introduction: To determine the agreement between intraocular pressure (IOP) measurements using conventional Goldmann applanation tonometry (GAT) and SUOER SW-500 Rebound Tonometer.
Methods: This was a retrospective observational study where 205 eyes of 106 glaucoma patients had their IOPs measured by 2 fellowship trained ophthalmologists. Data were analyzed using the Bland-Altman method of differences.
Natl Sci Rev
June 2024
Department of Materials Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, China.
High intraocular pressure (IOP) is one of the high-risk pathogenic factors of glaucoma. Existing methods of IOP measurement are based on the direct interaction with the cornea. Commercial ophthalmic tonometers based on snapshot measurements are expensive, bulky, and their operation requires trained personnel.
View Article and Find Full Text PDFMed J Malaysia
March 2024
Universitas Indonesia, Faculty of Medicine, Jakarta, Indonesia.
Medicine (Baltimore)
September 2023
Department of Ophthalmology, Phramongkutklao Hospital, Phramongkutklao College of Medicine, Bangkok, Thailand.
Intraocular pressure (IOP) is one of the most crucial aspects for diagnosis and treatment plan among patients with glaucoma. Although the gold standard for IOP measurement is Goldmann applanation tonometer (GAT)[1], it must be mounted to a slit lamp biomicroscope. However, rebound tonometer has become popular due to its ease of operation and portable design, does not require topical anesthesia, and results do not differ significantly from those of GAT[2].
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!