106 unicondylar knee replacement tibial components were retrieved and analyzed for the amount and type of polyethylene wear. Three different designs were retrieved which had essentially the same femorotibial conformity. Each design showed a characteristic failure pattern. The polyethylene of PCA tibial components showed serious delamination after only short durations, as a result of heat pressing. St Georg sledge prostheses showed some delamination after 4 years' duration due to sub-surface cracks which were initiated by fusion defects in the polyethylene; metal backing of the components did not affect delamination of this prosthesis. The Marmor designs showed the least wear, with shiny depressions and surface pitting; no delamination was observed in the Marmor prosthesis. Molecular weight determination by gel permeation chromatography and analysis of crystallinity using Fourier transformation infra-red spectroscopy demonstrated that St George polyethylene had higher molecular weight and crystallinity than Marmor polyethylene. In some of the components investigated, crystallinity and molecular weight of the polyethylene were reduced under the wear track when compared with the unworn polyethylene. Since fusion defects may cause delamination of polyethylene we urge manufacturers to reduce the number of such defects.

Download full-text PDF

Source
http://dx.doi.org/10.3109/17453679209154776DOI Listing

Publication Analysis

Top Keywords

tibial components
12
molecular weight
12
polyethylene
9
polyethylene wear
8
unicondylar knee
8
fusion defects
8
components
5
delamination
5
wear unicondylar
4
knee prostheses
4

Similar Publications

Introduction: As the number of revision total knee arthroplasties (rTKA) continues to rise, there is increasing interest in the use of contemporary rotating hinge prostheses. These devices often incorporate porous cones to fill bone defects and enhance long-term fixation. This study evaluated the clinical and functional outcomes and survivorship in rTKA patients utilizing a rotating hinge prosthesis with flexible titanium (FT) cones, porous tantalum (PT) cones, or no cones.

View Article and Find Full Text PDF

: Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) uses preoperative three-dimensional imaging to create cutting blocks tailored to patient anatomy. However, there is debate regarding the additional benefits of PSI in terms of improved alignment or functional outcomes compared to using conventional instruments. Although PSI design has undergone continuous development, the improvements have not been incorporated.

View Article and Find Full Text PDF

Background: Many patients with a lower limb socket-suspended prothesis experience socket-related problems, such as pain, chronic skin conditions, and mechanical problems, and as a result, health-related quality of life (HRQoL) is often negatively affected. A bone-anchored prosthesis can overcome these problems and improve HRQoL, but these prostheses have potential downsides as well. A valid and reliable tool to assess potential candidates for surgery concerning a favorable risk-benefit ratio between potential complications related to bone-anchored prostheses and improvements in HRQoL is not available yet.

View Article and Find Full Text PDF

In functionally aligned total knee arthroplasty, femoral component rotation follows the transepicondylar axis to achieve flexion balance.

Knee Surg Sports Traumatol Arthrosc

January 2025

Clinical Research Department, Sydney Knee Specialists, Kogarah, New South Wales, Australia.

Purpose: In functionally aligned (FA) total knee arthroplasty (TKA), femoral component rotation (FCR) is personalised to optimise flexion gap balance. As axial malalignment has been attributed to patellofemoral complications, this study assessed FA FCR in relation to the surgical transepicondylar axis (TEA) and early implant survivorship.

Methods: We analysed 446 robotic-assisted primary TKAs in 393 patients using FA with preresection gap balancing.

View Article and Find Full Text PDF

Background: In medial mobile-bearing unicompartmental knee arthroplasty (MB-UKA), the position of the bearing does not correspond to the planned position which will increasing the risk of bearing dislocation. This study aimed to explore the relationship between the malposition of the femoral and tibial components and the phenomenon of bearing deviation using postoperative radiological measurements.

Methods: One hundred twenty patients who underwent mobile-bearing uni-compartmental knee arthroplasty (MB-UKA) at our hospital between January and August 2023 were enrolled in this retrospective study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!