Diffraction gratings affect the absolute phase of light in a way that is not obvious from the usual derivation of optical paths using the grating equation. For example, consider light which encounters first one and then the second of two parallel gratings. If one grating is moved parallel to its surface, the phase of the light diffracted from the grating pair is shifted by 2pi each time the grating is moved by one grating constant, even though the geometric path length is not altered by the motion. This additional phase shift must be included when incorporating diffraction gratings in interferometers.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.95.013901DOI Listing

Publication Analysis

Top Keywords

grating equation
8
diffraction gratings
8
phase light
8
grating moved
8
grating
6
phase
4
phase effects
4
effects diffraction
4
light
4
diffraction light
4

Similar Publications

This Letter discusses the limitations of immersion-free recording schemes for holographic waveguide displays. Traditional holographic recording of waveguides requires recording angles exceeding the critical angle of the hologram-cladding interface. Achieving these angles necessitates edge-lit exposure using prisms and immersion liquids, which are challenging for roll-to-roll mass production and hinder widespread adoption.

View Article and Find Full Text PDF

The curing process of hair-pin motor stator insulation is critical, as residual stress increases the risk of partial discharge and shortens a motor's lifespan. However, studies on the stress-induced defects during insulation varnish curing remain limited. This research integrates three-dimensional numerical simulations and experimental analysis to develop a curing model based on unsaturated polyester imide resin, aiming to explore the mechanisms of residual stress formation and optimization strategies.

View Article and Find Full Text PDF

A wavelength demodulation method for ultra-short fiber Bragg grating (US-FBG) sensors based on an arrayed waveguide grating (AWG) and a convex optimization algorithm is proposed and demonstrated. Instead of measuring the output power ratio of the two adjacent AWG channels as previously done, in this work the wavelength demodulation is realized by reconstructing the US-FBG spectrum. The principle of spectral reconstruction involves using an AWG to sample the spectral information of US-FBG and constructing underdetermined matrix equations with the obtained prior information on transmission responses and the detected output power from multiple AWG channels.

View Article and Find Full Text PDF

Simultaneous generation of first- to fourth-order OAM modes based on a cascaded preset-twist long-period fiber grating.

Nanophotonics

July 2024

Institute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin 300350, China.

We propose and demonstrate the simulation and fabrication of an all-fiber orbital angular momentum (OAM) mode converter capable of generating first- to fourth-order modes simultaneously, which is realized by inscribing a cascaded preset-twist long-period fiber grating (CPT-LPFG) in a six-mode fiber utilizing a CO laser. A new segmented Runge-Kutta method is proposed to simulate the preset-twist long-period fiber gratings. By calculating the twist angle and relative coupling coefficient for each pitch and then solving the coupled mode equations utilizing the Runge-Kutta algorithm.

View Article and Find Full Text PDF

Quantitative phase microscopies: accuracy comparison.

Light Sci Appl

October 2024

Institut Fresnel, CNRS, Aix Marseille Univ, Centrale Med, Marseille, France.

Article Synopsis
  • Quantitative phase microscopies (QPMs) enhance bio-imaging by providing critical data on mass distribution and transport, which is not achievable through fluorescence techniques and are label-free, avoiding issues like photobleaching.!*
  • The review compares eight QPM techniques, including digital holographic microscopy and phase-shifting interferometry, focusing on their accuracy and measurement capabilities using a custom-developed numerical toolbox for simulations.!*
  • Results indicate that DHM and PSI are robust against artefacts but can be affected by coherent noise, while other techniques show a balance between measurement precision and accuracy, with some experiencing limitations due to inherent artefacts, especially with larger samples like eukaryotic cells.!*
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!