Nested tungsten wire arrays (20-mm on 12-mm diam.) are shown for the first time to operate in a current-transfer mode at 16-19 MA, even for azimuthal interwire gaps of 0.2 mm that are the smallest typically used for any array experiment. After current transfer, the inner wire array shows discrete wire ablation and implosion characteristics identical to that of a single array, such as axially nonuniform ablation, delayed acceleration, and trailing mass and current. The presence of trailing mass from the outer and the inner arrays may play a role in determining nested array performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevLett.94.225003 | DOI Listing |
ACS Appl Mater Interfaces
January 2022
School of Mechanical and Mining Engineering, The University of Queensland, St Lucia, Queensland 4072, Australia.
J Mass Spectrom
April 2019
FAU Erlangen-Nuremberg, Institute of Particle Technology, Erlangen, Germany.
The presence of electrochemical reactions occurring in an electrospray processes at the point where the current enters the liquid is discussed since the early 1990's. This current transfer to the liquid results in oxidation or reduction of either electrolyte species in the liquid sprayed or of the electrode material in contact with the liquid. As a result, new chemical species are generated.
View Article and Find Full Text PDFSensors (Basel)
October 2017
MOE Key Laboratory of Fundamental Physical Quantities Measurement & Hubei Key Laboratory of Gravitation and Quantum Physics, School of Physics, Huazhong University of Science and Technology, Wuhan 430074, China.
A new and simple method to adjust the scale factor of a magnetic force feedback accelerometer is presented, which could be used in developing a rotating accelerometer gravity gradient instrument (GGI). Adjusting and matching the acceleration-to-current transfer function of the four accelerometers automatically is one of the basic and necessary technologies for rejecting the common mode accelerations in the development of GGI. In order to adjust the scale factor of the magnetic force rebalance accelerometer, an external current is injected and combined with the normal feedback current; they are then applied together to the torque coil of the magnetic actuator.
View Article and Find Full Text PDFRev Sci Instrum
September 2014
MOE Key Laboratory of Fundamental Quantities Measurement, School of Physics, Huazhong University of Science and Technology, Wuhan 430074, China.
Gravity gradient measurement makes use of the difference between the outputs of pairs of linear accelerometers, which results in cancelling out the common mode accelerations caused by mounting platform and external environment. One of the key technologies is to match the acceleration-to-voltage or acceleration-to-current transfer functions of the pairs of the accelerometers to an extremely high degree of accuracy. The differential signals then make the gravity gradients observable.
View Article and Find Full Text PDFScientificWorldJournal
June 2014
Faculty of Engineering, King Mongkut's Institute of Technology Ladkrabang (KMITL), Bangkok 10520, Thailand.
This paper describes the conception of the current follower transconductance amplifier (CFTA) with electronically and linearly current tunable. The newly modified element is realized based on the use of transconductance cells (G(m)s) as core circuits. The advantage of this element is that the current transfer ratios (i(z)/i(p) and i(x)/i(z)) can be tuned electronically and linearly by adjusting external DC bias currents.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!